14
INSTALLATION & TECHNICAL MANUAL
START-UP
POWER UP
•
The Aurora has no ON/OFF button or switch. Plugging the unit into AC
power will turn the unit ON.
•
Disconnecting AC power will turn the unit OFF.
RESET BUTTON
•
The RESET button on the Controller board allows the Technician to cycle
power on the unit without disconnecting/connecting AC power.
AUTO-LEARN
•
On power up, the Aurora automatically enters Auto-Learn Mode, analyzing
the serial communications and string type.
•
The indicator’s output string must contain number characters. An STX
character (ASCII 02) and/or CR character (ASCII 13) must also be
included.
•
Once Auto-Learn is successful (about 10 seconds after power up) the
Aurora will display the current weight.
LEARN BUTTON
•
If Automatic Start-up Auto-Learn is disabled, the LEARN button on the
Controller board must be pressed to enter Auto-Learn Mode.
NOTE: Automatic Start-up Auto-Learn may be disabled for custom
applications. See Switch 6: Start-up Auto-Learn, on
page 17.