63
63
6618-3201
Register
Function
Range
Units
Saved
Default
Note
S12
Escape
Prompt Delay
0–255
20 ms
*
50
Specifies the delay time
required – after the entry of
the escape sequence – for
the modem to recognize
the escape sequence as
valid. The guard time also
dictates how quickly the
escape characters must be
entered, since the interval
between each entry of the
three characters must be
of shorter duration than
that specified for the guard
time. The value can range
between 0–255, the unit
corresponds to 0.02 sec.
In case of s12 = 0,
the guard time after +++ is
1 sec, no guard time check-
ing between the +’s is done.
This is the default value.
S13
Number of
synchronisa-
tion attempts
0–255
*
0
In leased line mode
register S13 defines the
number of synchronization
attempts before going idle.
Number of synchronisation
attempts = 0 means endless
loop.
Summary of Contents for TD-36