45
45
6618-3201
*WIOL – Generic I/O list
Supported by:
TD-36 485
Description:
This command is used to program the list of I/O entries with parameters and data.
Syntax:
AT*WIOL = <entry>,<service>,<flag>,<timeout>,<priority>,<”data1”>,<”data2”>,<data
3>, <data4>,<data5>,<data6>
AT*WIOL = ?
AT*WIOL=n?
List all table entries. Listing will present a short form table of the entire I/O list. Too see
the full field of the data parameter, list only an entry in the lis
AT*WIOL?
Parameters:
<entry>
I/O entry number, up to 10 entries can be defined.
<service>
I/O entry service
0 = NONE
No service defined for this entry
1 = DIAL
Makes a connection to the number defined in <data1>
2 = SMS
<data1>
Destination number of the SMS
<data2>
SMS-message.
<data3>
SMS service provider number
<data4>
SMS protocol type (0 = NONE,1 = UCP,2 = TAP)
<data5>
Password if required by provider.
3 = TEXT
Make a connection to number defined in
<data1>
and transfer text
defined in
<data2>
.
4 = EMAIL
Reserved for future use, service not implemented
5 = OUT
Make a connection to the number defined in
<data1>
and set/pulse
the remote output according to pattern defined in string defined in
<data2>
. The connection is terminated after the pattern is trans-
ferred.
6 = CMD
AT command specified by
<data1>
is executed when the entry is
trigged
7 = TRANS
Makes a connection to number defined by
<data1>
,
I/O is transferred transparently between the two units. The trans-
parent mode must be ended by a timeout.
Summary of Contents for TD-36