* S-registers
Register
Function
Range
Units
Saved
Default
Note
S0
Rings to
Auto-Answer
0–255
Rings
*
2
Determines the number of
rings before taking the line.
Assigning a value from 1 to
255 places the modem in
auto-answer mode. Setting
S0 to 0 disables auto-answer
mode.
S1
Ring Counter 0–255
Rings
0
S1 is incremented each time
the modem detects a ring
signal on the telephone
line. It is cleared if no rings
occur over any eight second
interval.
S2
Escape
Character
ASCII
0–255
ASCII
*
43 (02Bh)
S2 holds the ASCII value of
the escape code. The default
value is 43 (ASCII “+”). S2
canbe set to any value from
0 to 127. To return to the
command state when the
escape code is disabled, the
distant modem must hang
up (local modem looses
carrier).
S3 Carriage
Return
Character
0–127
ASCII
*
13 (0Dh)
S3 holds the ASCII value of
the carriage return char-
acter. Default a value of 13
is used. If the data terminal
equipment is non standard, a
different value can be used.
This character serves as the
command line terminator
and the result code termina-
tor. This character must not
be set to a value greater
than 127.
S4
Line Feed
Character
0–127
ASCII
*
10 (0Ah)
S4 holds the ASCII value of
the line feed character. The
default value is 10. This char-
acter must not be set to a
value greater than 127.