17
17
6618-3201
In – Request identification information
Supported by:
TDW-33
TD-36
TD-36 485
TR-36
Description:
This command causes the product to transmit one or more lines of specific information
text.
Syntax:
ATI<n>
Parameters:
<n>
0:
Display max line speed.
4: Display
manufacturer
identification.
5: Display
country
code.
6:
Display revision identification for modem modulation code
8: Display switch settings
9: Display
Westermo
Application
Software
revision
identification.
Other values: “OK” string is sent back.
Command example Possible responses
Note
ATI0
33600
Max line speed
OK
ATI4 WESTERMO
Modem
manufactor
TELEINDUSTRI
AB
identifier
OK
ATI6 BSMW310_BF533_bfbsmw310_5457OK
Revision
identification
OK
for modem modula-
tion code
ATI8
000 000 000 000
Switch settings
OK
Each DIP switch
displayed as a decimal
value. S1 S2 S3 S4
Notice switch setting
is only reed at power-
up and ATZ
ATI9 4101-0201
Westermo
SW
OK
release
ERROR
Otherwise
S register: None