43
43
6618-3201
*WI – Information string
Supported by:
TDW-33
TD-36
TD-36 485
TR-36
Description
The command enable or disable the sending of an information string to the DTE or
remote DCE according to the parameter supplied. The parameter values, if valid, are
stored in the active profile.
Syntax:
AT*WI=<”string”>,<mode>
Parameters:
<”string”>
Information string [0-40 characters].
<mode>
Information string mode [0-4].
0:
Disable the function
1:
Send information string to remote DCE when inactivity timer (S30) expires.
2:
Send information string to remote DCE after connect message or DCD.
3:
Send information string to DTE when inactivity timer (S30) expires.
4:
Send information string to DTE after connect message or DCD.
Other values: “ERROR” string is sent back.
Command example
Possible responses
Note
AT* WI=”Info string 1”,1
OK
Send info string to
remote DCE when
inactivity timer expires.
AT* WI =”Info string”,4
OK
Send info string to DTE
when
connected.
AT* WI =””
OK
Delete info string and
disable
function
(mode to 0)
AT*WI=,0 OK
Disable
function
AT*WI=,1
OK
Enable function with
mode set to 1
AT* WI?
*WI: string, mode
List parameters
OK
AT* WI =?
* WI : (0-40 CHAR),
List command parameters
(0-255)
OK
ERROR
Otherwise
S register: See S30
Summary of Contents for TD-36
Page 83: ......