66
66
6618-3201
Register
Function
Range
Units
Saved
Default
Note
S30
Disconnect
Inactivity
Timer
0–255
10 s
*
0
This register has to be rede-
fined. 10 s.
S31
Results Bit
Mapped
Options
*
192
Definition: S31
Indicates the status of com-
mand options.
Bit 0 Single Line Connect
Message \Vn
0 = \V0
1 = \V1
Bits 1 Reserved
Bits 2–3 Error Connect
Message messages
0 = W0 (Default)
1 = W1
2 = W2
Bits 4–5 Not Used
Bit 6-7 Reserved
S36 LAPM
Failure
Control
– –
*
7
Definition:
S36
Bits 0–2 indicates what
should happen upon a
LAPM failure. These fallback
options are initiated imme-
diately upon connection if
S48 = 128.0.
Bits 0–2
0 = Modem disconnects.
1 = Modems Stays on-line
and a direct mode connec-
tion will be established.
2 = Reserved.
3 = Modem stays on-line
and Normal Mode connec-
tion will be established.
4 = An MNP connection is
attempted and if it fails, the
modem disconnects.
5 = An MNP connection is
attempted and if it fails, a
direct mode connection is
established.
6 = Reserved.
7 = An MNP connection
is attempted and if it fails,
normal mode connection
is established.
Bits 3–7 Reserved.
Summary of Contents for TD-36
Page 83: ......