Section SDSĆ548Ć6LNĆ204

030Ć101328 Rev. A

R

0208I4RA

2

S

Automatic 4Ćtone alignment capability; Auto Align is

activated via a frontĆpanel TEST switch during the first

five minutes of initial powerĆup or via command mode by

sending 1804 Hz to INTELIPORT.

S

Automatically adjusts amplitude response characteristics

(up to 15.3 dB, referenced at 1004 Hz) to meet C5 condiĆ

tioning requirements.

S

Unit identification tone (alternating 1014 Hz/414 Hz)

identifies unit being accessed for maintenance testing as

INTELIPORT.

S

Remotely adjustable XMT OUT Level setting in 0.5 dB

(gain/loss) increments.

S

FullĆrange transponder operation (300 to 3200 Hz) with

quiet termination permits remote testing of noise and

tone level measurements at TLP or DLP.

S

FrontĆpanel TEST switch used to activate INTELIĆ

PORT's wire test mode for verifying station wiring.

S

Sealing current Supply/Off/Term operation.

S

NonĆvolatile memory retains programmed information in

the event of power loss.

S

Mounts in one position of a Westell Type 550 (TypeĆ400

equivalent) or 200 Mechanics

r

 mounting.

S

Operates from Ć22 to Ć56 Vdc at 95 mA maximum or

from 20 to 28 Vac at 115 mA maximum.

S

7Ćyear warranty.

2.

APPLICATIONS

The SDS5486LN provides an interface between a 4Ćwire facility

and a 600Ćohm 2W or 4W data modem. The SDS5486LN is norĆ

mally located on the same premises as the modem. The integral

microprocessor circuit controls all functions of the unit. The preĆ

cision oscillator circuit generates test tones during testing and

alignment.

2.1

Command Mode

INTELIPORT incorporates a command mode from which all

functions except manual and toneĆactivation of the loopback cirĆ

cuit are accessed. The command mode is the operational state

in which INTELIPORT monitors its transmission paths for inĆ

coming  frequencies  and  interprets  these  frequencies  as

commands to carry out specific functions. The command mode

is activated from the STC by sending 2713Hz for more than 30

seconds. INTELIPORT responds by sending 1014Hz indicating

command mode initiation. If the tone is present for more than

2.0  seconds  but  less  than  30  seconds,  INTELIPORT  sends  a

1Ćsecond alternating tone of 1014Hz/414Hz and enters the loopĆ

back mode of operation.

2.2

XMT OUT Level Adjust

The  operating  levels  for  Westell's  SDS5486LN  are  given  in

Table 1. The Transmit Out level can be remotely adjusted to acĆ

commodate any level from +7 to Ć16 dBm. The XMT OUT level

can be adjusted by adding either gain or loss in 0.5dB increments

or can be set to achieve a Ć16 dBm level (see paragraphs 3.13 thru

3.16).

PORT

LEVELS (IN DBM)

PORT

TLP

DLP

RCV IN

+5 to Ć10

Ć8 to Ć23

RCV OUT

Ć3

Ć16

XMT IN

+13

0

XMT OUT

+5

 Ć8

*The XMT OUT level can be remotely adjusted for any level from +7 to Ć16 dBM (TLP) or Ć6 to

Ć29 dBM (DLP)

Table 1.    Operating Levels

2.3Alignment (Remote and Automatic)

The SDS5486LN features both remote and automatic alignment

capability.

2.3.1 Remote Alignment

The Serving Test Center (STC) can align the circuit to either

three tones or four tones.

Ć  NOTE Ć

FourĆtone alignment allows a more accurate alignment when inĆ

terfacing long sections of loaded cable or a mixture of loaded and

nonĆloaded cable facilities.

2.3.2 Automatic 4Ćtone Alignment

AutoĆAlign is activated from onĆsite via the frontĆpanel TEST

switch, during the first five minutes of initial powerĆup. AutoĆ

Align is also activated via the command mode by sending 1804

Hz to INTELIPORT.

3.

CIRCUIT/FUNCTIONAL OPERATION

Refer to Figure 2, SDS5486LN (Issue 4) Block Diagram.

3.1

LED Status Indicators

INTELIPORT has six, frontĆpanel LEDs that provide a quick

visual indication of the units status and mode. Table 2 provides

a brief summary of the LED functions.

Summary of Contents for INTELIPORT I SDS5486LN

Page 1: ...28 and updates the company contact information Whenever this practice is updated the reason will be stated in this paragraph 1 3 Product Purpose and Description Westell s INTELIPORT I Model SDS5486LN...

Page 2: ...T monitors its transmission paths for in coming frequencies and interprets these frequencies as commands to carry out specific functions The command mode is activated from the STC by sending 2713Hz fo...

Page 3: ...T DATA DETECTOR SEALING CURRENT LB TEK5 TEK6 23 21 MICROPROCESSOR MLBG GND PWR 35 17 19 S1 SUPPLY OFF TERM LPBK AMP S3 A 2W 4W 1200 600 150 150 600 1200 DTT ALIGN LPBK TEST HYBRID XMT OUT LEVEL ADJUST...

Page 4: ...TELIPORT s intelligent functions which include XMT OUT Level Adjust mode remote alignment mode TLP or DLP Quiet Term Trans ponder mode or the STC can exit the command mode and return to idle NOTE The...

Page 5: ...ioning The ramp up tone also occurs whenever a 20 minute timer circuit times out due to inactivity that is no tone sent to INTELIPORT during a test function equipped with the 20 minute time out featur...

Page 6: ...and 3 14 above After obtaining the required XMT OUT level the STC must send 2713Hz for 0 9 seconds minimum to return to command mode 3 17 Quiet Term Transponder Operation INTELIPORT s Quiet Term Trans...

Page 7: ...pletion if no tone is sent during the 20 minute time frame INTELIPORT after 20 minutes sends a ramp up tone drops out of the Quiet Term Transponder mode and returns to idle If release is desired befor...

Page 8: ...the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines 5 1 Installer Connections When installing the unit in Westell s pre wired US...

Page 9: ...ndard test procedures for digital interface equipment using the KS 108 109 or equivalent re ceiver and transmitter data test sets This equipment should not be field repaired If the equipment is suspec...

Page 10: ...of 1014 Hz 414 Hz and enters loopback 4 Remote Manual Alignment Mode From command mode verify record level received at 1014 Hz then send 1004 Hz to INTELIPORT Upon detecting 1004 Hz INTELIPORT return...

Page 11: ...2222 Hz is detected and removed To add Loss Send and remove 2111 Hz INTELIPORT re adjusts output level by adding 0 5 dB of loss If more loss is required repeat the process of sending and removing 211...

Page 12: ...de send 1004 Hz 4 INTELIPORT returns 2814 Hz 5 Record level at 2814 Hz in Column B then send 2804 Hz 6 INTELIPORT returns 414 Hz 7 Record level at 414 Hz in Column B then send 404 Hz 8 INTELIPORT retu...

Page 13: ...All tones sent from STC are TLP unless stated otherwise TLP Transponder Mode 804 Hz Activated 1 While in command mode send 804 Hz 2 INTELIPORT applies quiet termination over the XMT IN port 3 STC perf...

Page 14: ...evel at the RCV demarcation point of Station A and Station Z STATION A SMAS SMAS STATION Z POINT B POINT C X X X X X X X X POINT A POINT D 5486LNI4 5486LNI4 OR EQUIVALENT 1 2 A B C D E F G H J A B C D...

Page 15: ...LP for 0 9 seconds minimum Station A returns to command mode 16 From SMAS Point A send 804 Hz at TLP When SMAS Point B goes quiet remove 804 Hz 17 Close SMAS access Point B to C 18 From SMAS Point D m...

Page 16: ...the warranty period for a nominal charge Contact Westell for details 9 SPECIFICATIONS 9 1 Ordering Specifications To order units call the telephone numbers shown in Paragraph 7 1 and please specify a...

Page 17: ...LP Transponder activated from command mode by sending 804Hz DLP Transponder activated from command mode by sending 1304Hz When activated INTELIPORT applies quiet termination and sets 20 minute timer c...

Page 18: ...MT OUT LEVEL TO 16dBm AFTER SETTING DESIRED XMT OUT LEVEL SEND 2713Hz FOR 0 9 SEC INTELIPORT RETURNS TO COMMAND MODE SEND 2713HZ FOR 0 9 SEC INTELIPORT RETURNS TO IDLE SEND 1804Hz START 3 TONE ALIGNME...

Reviews: