background image

Section SDSĆ548Ć6LNĆ204

030Ć101328 Rev. A

R

0208I4RA

10

STEP

ACTION

STEP

ACTION

INSTALLER'S PROCEDURES

1.

Set option switches as required per Circuit Layout Record (CLR) card. Install the unit and apply power. Verify PWR LED

ON SC LED ON (if applicable) and ALIGN/LPBK FAIL/TEST RCV and XMT LEDs are OFF NOTE: If FAIL/TEST LED is

y

y

y

ON, SC LED ON (if applicable), and ALIGN/LPBK, FAIL/TEST, RCV and XMT LEDs are OFF. NOTE: If FAIL/TEST LED is

flashing, press frontĆpanel TEST switch. If FAIL/TEST LED is ON steady, replace unit and repeat procedures.

Wire Test Mode

CAUTIONĆINTELIPORT places 1014Hz tone on the transmission pairs when TEST mode is activated. Be sure INTELIPORT

is not connected to an inĆservice circuit where this tone may cause interference.

Momentarily press the frontĆpanel TEST switch (less than five seconds) and release. Verify FAIL/TEST LED is flashing. ConĆ

2.

Momentarily press the frontĆpanel TEST switch (less than five seconds) and release. Verify FAIL/TEST LED is flashing. ConĆ

nect TMS with builtĆin speaker, or other suitable listening device, to:

PORT

4W APPLICATIONS

2W APPLICATIONS

RCV IN

verify

Continuous 1014 Hz

Continuous 1014 Hz

RCV OUT

verify

Continuous 1014 Hz

XMT IN

if

I

d

H

I

d

H

RCV OUT

verify

Continuous 1014 Hz

XMT IN

verify

Interrupted 1014 Hz

Interrupted 1014 Hz

XMT OUT

verify

Interrupted 1014 Hz

Interrupted 1014 Hz

When tones are verified, press TEST switch to end test mode. Test mode automatically times out one hour after initial acĆ

tivation if switch is not pressed a second time.

Note: In 2W applications RCV OUT and XMT IN port utilize same transmission pairs (XMT IN).

3

Serving Test Center's Procedures

Send 2713 Hz (>30 sec.*) at TLP to INTELIPORT's RCV IN port. Verify steady 1014 Hz at +5dBm (TLP) from INTELIPORT.

3.

Send 2713 Hz (>30 sec. ) at TLP to INTELIPORT s RCV IN port. Verify steady 1014 Hz at +5dBm (TLP) from INTELIPORT.

remove 2713 Hz. Command mode initiated.

Note: if 2713 Hz is present for two sec. but removed in less than 30 seconds, INTELIPORT sends a 1Ćsecond alternating

tone of 1014 Hz/414 Hz and enters loopback.

4

Remote (Manual) Alignment Mode

From command mode, verify/record level received at 1014 Hz, then send 1004 Hz to INTELIPORT.

Upon detecting 1004 Hz, INTELIPORT returns 2814 Hz.

Verify/record level received at 2814 Hz, then send 2804 Hz to INTELIPORT

Upon detecting 2804 Hz,  INTELIPORT returns 414 Hz.

Verify/record level received at 414 Hz, then send 404 Hz to INTELIPORT.

Upon detecting 404 Hz, INTELIPORT returns 1814 Hz for 120 seconds.

Verify/record level received at 1814 Hz. At this point, STC has option of aligning to 3 tones or 4 tones.

3Ćtone alignment: Ignore 1814 Hz tone. After 120 seconds, 11814 Hz tone from INTELIPORT times out.

INTELIPORT aligns to 3 tones, returns a rampĆup or rampĆdown tone*, applies quiet termination for one second,

then enters loopback. NOTE: 120Ćsecond timer can be bypassed by sending 1004 Hz during the 120Ćsecond 

time frame.

4Ćtone alignment: Send 1804 Hz in response to INTELIPORT'S 1814 Hz in response to INTELIPORT's 1814 Hz 

within the 120 time frame INTELIPORT aligns to 4 tones returns a ramp up or ramp down* applies quiet

4.

within the 120 time frame. INTELIPORT aligns to 4 tones, returns a rampĆup or rampĆdown*, applies quiet        

termination for one second, then enters loopback.

NOTE: Upon completion, if a level other than +5dBm (TLP) is required at the XMT OUT port the STC should access the

XMT OUT Level Adjust mode to set the desired output level.

Note: RampĆup tone (314 Hz to 3014 Hz) indicates alignment is within C5 conditioning. RampĆdown tone (3014 Hz to 314

Hz) indicates alignment is not within C5 conditioning.

AutoĆAlign Mode

Note: AutoĆalign is initiated by pressing the frontĆpanel TEST switch (more than five seconds) during the first five minutes

of initial powerĆup, or via command mode by sending 1804 Hz to INTELIPORT.

When activated, INTELIPORT sends 2913 Hz out of the RCV IN port to near end to put near end into command mode.

Near end, upon entering command mode, returns command mode tone to INTELIPORT. With both Stations set, tones are

automatically sent and received between both ends. Upon completion (approximately two to three minutes), INTELIPORT

returns to idle. Near end also returns to idle.

Table 6.    Testing and Alignment Procedures

Summary of Contents for INTELIPORT I SDS5486LN

Page 1: ...28 and updates the company contact information Whenever this practice is updated the reason will be stated in this paragraph 1 3 Product Purpose and Description Westell s INTELIPORT I Model SDS5486LN...

Page 2: ...T monitors its transmission paths for in coming frequencies and interprets these frequencies as commands to carry out specific functions The command mode is activated from the STC by sending 2713Hz fo...

Page 3: ...T DATA DETECTOR SEALING CURRENT LB TEK5 TEK6 23 21 MICROPROCESSOR MLBG GND PWR 35 17 19 S1 SUPPLY OFF TERM LPBK AMP S3 A 2W 4W 1200 600 150 150 600 1200 DTT ALIGN LPBK TEST HYBRID XMT OUT LEVEL ADJUST...

Page 4: ...TELIPORT s intelligent functions which include XMT OUT Level Adjust mode remote alignment mode TLP or DLP Quiet Term Trans ponder mode or the STC can exit the command mode and return to idle NOTE The...

Page 5: ...ioning The ramp up tone also occurs whenever a 20 minute timer circuit times out due to inactivity that is no tone sent to INTELIPORT during a test function equipped with the 20 minute time out featur...

Page 6: ...and 3 14 above After obtaining the required XMT OUT level the STC must send 2713Hz for 0 9 seconds minimum to return to command mode 3 17 Quiet Term Transponder Operation INTELIPORT s Quiet Term Trans...

Page 7: ...pletion if no tone is sent during the 20 minute time frame INTELIPORT after 20 minutes sends a ramp up tone drops out of the Quiet Term Transponder mode and returns to idle If release is desired befor...

Page 8: ...the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines 5 1 Installer Connections When installing the unit in Westell s pre wired US...

Page 9: ...ndard test procedures for digital interface equipment using the KS 108 109 or equivalent re ceiver and transmitter data test sets This equipment should not be field repaired If the equipment is suspec...

Page 10: ...of 1014 Hz 414 Hz and enters loopback 4 Remote Manual Alignment Mode From command mode verify record level received at 1014 Hz then send 1004 Hz to INTELIPORT Upon detecting 1004 Hz INTELIPORT return...

Page 11: ...2222 Hz is detected and removed To add Loss Send and remove 2111 Hz INTELIPORT re adjusts output level by adding 0 5 dB of loss If more loss is required repeat the process of sending and removing 211...

Page 12: ...de send 1004 Hz 4 INTELIPORT returns 2814 Hz 5 Record level at 2814 Hz in Column B then send 2804 Hz 6 INTELIPORT returns 414 Hz 7 Record level at 414 Hz in Column B then send 404 Hz 8 INTELIPORT retu...

Page 13: ...All tones sent from STC are TLP unless stated otherwise TLP Transponder Mode 804 Hz Activated 1 While in command mode send 804 Hz 2 INTELIPORT applies quiet termination over the XMT IN port 3 STC perf...

Page 14: ...evel at the RCV demarcation point of Station A and Station Z STATION A SMAS SMAS STATION Z POINT B POINT C X X X X X X X X POINT A POINT D 5486LNI4 5486LNI4 OR EQUIVALENT 1 2 A B C D E F G H J A B C D...

Page 15: ...LP for 0 9 seconds minimum Station A returns to command mode 16 From SMAS Point A send 804 Hz at TLP When SMAS Point B goes quiet remove 804 Hz 17 Close SMAS access Point B to C 18 From SMAS Point D m...

Page 16: ...the warranty period for a nominal charge Contact Westell for details 9 SPECIFICATIONS 9 1 Ordering Specifications To order units call the telephone numbers shown in Paragraph 7 1 and please specify a...

Page 17: ...LP Transponder activated from command mode by sending 804Hz DLP Transponder activated from command mode by sending 1304Hz When activated INTELIPORT applies quiet termination and sets 20 minute timer c...

Page 18: ...MT OUT LEVEL TO 16dBm AFTER SETTING DESIRED XMT OUT LEVEL SEND 2713Hz FOR 0 9 SEC INTELIPORT RETURNS TO COMMAND MODE SEND 2713HZ FOR 0 9 SEC INTELIPORT RETURNS TO IDLE SEND 1804Hz START 3 TONE ALIGNME...

Reviews: