LED

ON

OFF

FLASHING

LED

ON

OFF

FLASHING

PWR

Power Applied

Power Not

Applied

NA

SC

Sealing CurĆ

rent Applied

Sealing CurĆ

rent Not ApĆ

plied

NA

ALIGN/

LPBK

Command

Mode, AlignĆ

ment Mode or

Transponder

Mode

Idle

Loopback

Mode

FAIL/

TEST

Logic Failure

Idle

 Test Mode

XMT

Receiving data

from EquipĆ

ment

Idle

NA

RCV

Transmitting

data to EquipĆ

ment

Idle

NA

Table 2.    Operating Levels LED Status Indicators

3.2

Option Switches

The SDS5486LN contains three option switches that must be set

to  the  required  position  before  the  unit  is  installed.  Option

switch S1 (Sealing Current) is used to select the appropriate

sealing current configuration (Supply/Off/Term). Option switch

S2 (Facility Impedance) is used to select the impedance of the

unit (150/600/1200 Ohms) that will match the impedance of the

4Ćwire facility. Option switch S3 (2W/4W) is used to set INTELIĆ

PORT's  internal  circuitry  to  properly  interface  the  2Ćwire  or

4Ćwire data modem equipment.

3.3

Unit Identification Tone

The SDS5486LN provides a unit identification feature that alĆ

lows the Test Center to verify which unit is being accessed. Upon

receiving 2713 Hz for more than two seconds, INTELIPORT

outputs an I.D. tone (one second of alternating 1014Hz/414 Hz)

identifying the circuit being accessed as Westell's INTELIPORT

I, Model SDS5486LN (Issue 4). At this point, if the 2713 Hz tone

is removed in less than 30 seconds INTELIPORT enters loopĆ

back.  If  2713  Hz  is  applied  for  more  than  30  seconds,

INTELIPORT enters command mode.

3.4

Command Mode

As  mentioned,  the  command  mode  is  activated  by  sending

2713Hz via the RCV IN port (RT and RR, pins 7 and 13, respecĆ

tively) for more than 30 seconds. NOTE: If 2713Hz is removed

in less than 30 seconds, INTELIPORT sends a 1Ćsecond alterĆ

nating tone of 1014Hz/414Hz and enters loopback.

Upon  detecting  2713Hz  for  more  than  30  seconds,  INTELIĆ

PORT enters the command mode and returns a steady 1014Hz

tone at +5 dBm (TLP) via the XMT OUT port (TT and TR, pins

41 and 47, respectively) indicating command mode initiation.

STC, at this point, removes the 2713Hz tone being sent to INTEĆ

LIPORT.

While in command mode, the STC can activate INTELIPORT's

intelligent  functions  which  include:  XMT  OUT  Level Adjust

mode, remote alignment mode, TLP or DLP Quiet Term/TransĆ

ponder mode or the STC can exit the command mode and return

to idle.

Ć NOTE Ć

The command mode is equipped with a 5Ćmin timer circuit.

If no tone is sent to INTELIPORT during the five minute time

frame, INTELIPORT sends an error tone (rampĆdown tone

from 3014 Hz to 314 Hz; holding 314 Hz for 10 seconds) and

returns to idle. The rampĆdown tone, in this case, indicates the

command mode has timed out via the 5Ćmin timeĆout feature.

.

3.5

Alignment Mode

INTELIPORT features both remote and automatic alignment

capability.  Remote  alignment  is  used  to  align  INTELIPORT

from the STC. Alignment is done at TLP and with respect to eiĆ

ther  three  tones  or  four  tones.  AutoĆAlign  is  used  to

automatically align INTELIPORT with an intelligent ETO at

the near end (ISQ4389LNI2 or AUA441LN). AutoĆAlign is also

done at TLP and with respect to four tones. Please note, howevĆ

er, that the autoĆalign feature is only initiated by pressing the

frontĆpanel TEST switch for more than five seconds and only

during the first five minutes of initial powerĆup. AutoĆAlign is

also activated from command mode by sending 1804Hz to INĆ

TELIPORT.

3.6

AutoĆAlign

As mentioned, AutoĆAlign is initiated during the first five minĆ

utes of initial powerĆup by pressing the frontĆpanel TEST switch

for more than five seconds or from command mode by sending

1804Hz to INTELIPORT. Upon initiating AutoĆalign mode, INĆ

TELIPORT then sends 2913Hz out the RCV IN port (pins 7,13)

to the near end ETO. Upon entering command mode, the ETO

will then return 1014Hz to INTELIPORT.

When  1014Hz  is  detected  from  the  near  end,  INTELIPORT

sends 1014Hz. Upon detecting 1014Hz from INTELIPORT, the

near end returns 2814Hz. Upon detecting 2814Hz from the near

end,  INTELIPORT  sends  2814Hz.  Upon  detecting  2814Hz

from INTELIPORT, the near end returns 414Hz. Upon detectĆ

ing 414Hz from the near end, INTELIPORT sends 414Hz.

At this point, if the near end has the capability of aligning to four

tones, the near end, upon detecting 414Hz from INTELIPORT,

returns 1814Hz to INTELIPORT. Upon detecting 1814Hz, INĆ

TELIPORT  sends  1814Hz.  Upon  detecting  1814Hz  from

INTELIPORT, both ends align to four tones.

Upon  completion  of  alignment  (approximately  two  to  three

minutes), INTELIPORT returns to idle. The near end also reĆ

turns to idle.

Summary of Contents for INTELIPORT I SDS5486LN

Page 1: ...28 and updates the company contact information Whenever this practice is updated the reason will be stated in this paragraph 1 3 Product Purpose and Description Westell s INTELIPORT I Model SDS5486LN...

Page 2: ...T monitors its transmission paths for in coming frequencies and interprets these frequencies as commands to carry out specific functions The command mode is activated from the STC by sending 2713Hz fo...

Page 3: ...T DATA DETECTOR SEALING CURRENT LB TEK5 TEK6 23 21 MICROPROCESSOR MLBG GND PWR 35 17 19 S1 SUPPLY OFF TERM LPBK AMP S3 A 2W 4W 1200 600 150 150 600 1200 DTT ALIGN LPBK TEST HYBRID XMT OUT LEVEL ADJUST...

Page 4: ...TELIPORT s intelligent functions which include XMT OUT Level Adjust mode remote alignment mode TLP or DLP Quiet Term Trans ponder mode or the STC can exit the command mode and return to idle NOTE The...

Page 5: ...ioning The ramp up tone also occurs whenever a 20 minute timer circuit times out due to inactivity that is no tone sent to INTELIPORT during a test function equipped with the 20 minute time out featur...

Page 6: ...and 3 14 above After obtaining the required XMT OUT level the STC must send 2713Hz for 0 9 seconds minimum to return to command mode 3 17 Quiet Term Transponder Operation INTELIPORT s Quiet Term Trans...

Page 7: ...pletion if no tone is sent during the 20 minute time frame INTELIPORT after 20 minutes sends a ramp up tone drops out of the Quiet Term Transponder mode and returns to idle If release is desired befor...

Page 8: ...the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines 5 1 Installer Connections When installing the unit in Westell s pre wired US...

Page 9: ...ndard test procedures for digital interface equipment using the KS 108 109 or equivalent re ceiver and transmitter data test sets This equipment should not be field repaired If the equipment is suspec...

Page 10: ...of 1014 Hz 414 Hz and enters loopback 4 Remote Manual Alignment Mode From command mode verify record level received at 1014 Hz then send 1004 Hz to INTELIPORT Upon detecting 1004 Hz INTELIPORT return...

Page 11: ...2222 Hz is detected and removed To add Loss Send and remove 2111 Hz INTELIPORT re adjusts output level by adding 0 5 dB of loss If more loss is required repeat the process of sending and removing 211...

Page 12: ...de send 1004 Hz 4 INTELIPORT returns 2814 Hz 5 Record level at 2814 Hz in Column B then send 2804 Hz 6 INTELIPORT returns 414 Hz 7 Record level at 414 Hz in Column B then send 404 Hz 8 INTELIPORT retu...

Page 13: ...All tones sent from STC are TLP unless stated otherwise TLP Transponder Mode 804 Hz Activated 1 While in command mode send 804 Hz 2 INTELIPORT applies quiet termination over the XMT IN port 3 STC perf...

Page 14: ...evel at the RCV demarcation point of Station A and Station Z STATION A SMAS SMAS STATION Z POINT B POINT C X X X X X X X X POINT A POINT D 5486LNI4 5486LNI4 OR EQUIVALENT 1 2 A B C D E F G H J A B C D...

Page 15: ...LP for 0 9 seconds minimum Station A returns to command mode 16 From SMAS Point A send 804 Hz at TLP When SMAS Point B goes quiet remove 804 Hz 17 Close SMAS access Point B to C 18 From SMAS Point D m...

Page 16: ...the warranty period for a nominal charge Contact Westell for details 9 SPECIFICATIONS 9 1 Ordering Specifications To order units call the telephone numbers shown in Paragraph 7 1 and please specify a...

Page 17: ...LP Transponder activated from command mode by sending 804Hz DLP Transponder activated from command mode by sending 1304Hz When activated INTELIPORT applies quiet termination and sets 20 minute timer c...

Page 18: ...MT OUT LEVEL TO 16dBm AFTER SETTING DESIRED XMT OUT LEVEL SEND 2713Hz FOR 0 9 SEC INTELIPORT RETURNS TO COMMAND MODE SEND 2713HZ FOR 0 9 SEC INTELIPORT RETURNS TO IDLE SEND 1804Hz START 3 TONE ALIGNME...

Reviews: