background image

Section SDSĆ548Ć6LNĆ204

030Ć101328 Rev. A 

R

0208I4RA

15

  1) Open SMAS access at Point D to A to C.

  2) From SMAS Point A, send 2713 Hz at TLP for more than 30 seconds. Station A sends 1014 Hz to SMAS Point B.

  3) From SMAS Point C, send 2713 Hz at TLP for more than 30 seconds. Station Z sends 1014 Hz to SMAS Point D.

  4) From SMAS Point C, send 804 Hz at TLP. When SMAS Point D goes quiet, remove 804 Hz.

  5) Close SMAS access Point D to A.

  6) From SMAS Point B, measure level at 1014 Hz and record in Column B.

  7) From SMAS Point C, send 1004 Hz at TLP.

  8) SMAS Point B will change to 2814 Hz. Measure level and record in Column B.

  9) From SMAS Point C, send 2804 Hz at TLP.

10) SMAS Point B will change to 414 Hz. Measure level and record in Column B.

11) From SMAS Point C, send 404 Hz at TLP.

12) SMAS Point B will change to 1814 Hz for 120 seconds. Measure level and record in Column B. STC now has option:

Perform 3ĆTone Alignment Ć

Ignore 1814 Hz tone from INTELIPORT. After 120 seconds, 1814 tone times out. INTELIPORT 

(Station A) aligns to 3 tones, sends rampĆup or rampĆdown tone, and enters loopback.

Perform 4ĆTone Alignment Ć 

From SMAS Point C, send 1804 Hz within 120 seconds. INTELIPORT (Station A) aligns to 4 

tones, sends rampĆup or rampĆdown tone, then enters loopback.

13) From SMAS Point C, send 404 Hz, 2804 Hz, 1004 Hz and, if required, 1804 Hz, one at a time. Measure level of each tone looped 

back by INTELIPORT  at Point B and record levels in appropriate spaces of Column C.

14) From SMAS Point C, send 2713 Hz at TLP for 0.9 seconds minimum. Station Z returns to command mode.

15) From SMAS Point A, send 2713 Hz at TLP for 0.9 seconds minimum. Station A returns to command mode.

16) From SMAS Point A, send 804 Hz at TLP. When SMAS Point B goes quiet, remove 804 Hz.

17) Close SMAS access Point B to C.

18) From SMAS Point D, measure level at 1014 Hz and record in Column F.

19) From SMAS Point A, send 1004 Hz at TLP

20) SMAS Point D will change to 2814 Hz. Measure and record level lin Column F.

21) From SMAS Point A, send 2804 Hz at TLP.

22) SMAS Point D will change to 414 Hz. Measure and record level lin Column F.

23) From SMAS Point A, send 404 Hz at TLP.

24) SMAS Point D will change to 1814 Hz for 120 seconds. Measure and record level in column F. STC now has option:

Perform 3ĆTone Alignment Ć

Ignore 1814 Hz tone from INTELIPORT. After 120 seconds, 1814 tone times out. INTELIPORT 

or equivalent unit (Station Z) aligns to 3 tones, sends rampĆup or rampĆdown tone, and enters 

loopback.

Perform 4ĆTone Alignment Ć 

From SMAS Point A, send 1804 Hz within 120 seconds. INTELIPORT or equivalent unit (Station 

Z) aligns to 4 tones, sends rampĆup or rampĆdown tone, and enters loopback.

25) From SMAS Point A, send 404 Hz, 2804 Hz, 1004 Hz and, if required, 1804 Hz, one at a time. Measure level of each tone looped 

back by INTELIPORT at Point D and record levels in appropriate spaces of Column G.

26) From SMAS Point A, send 2713 Hz at TLP for 0.9 seconds minimum. Station A returns to command mode.

27) From SMAS Point A, send 2713 Hz at TLP for 0.9 seconds minimum. Station A released.

28) From SMAS Point C, send 2713 Hz at TLP for 0.0 seconds minimum. Station Z returns to command mode.

29) From SMAS Point C, send 2713 Hz at TLP for 0.9 seconds minimum. Station Z released.

30) Close SMAS access Point D to A and B to C.

31) Perform calculations in Columns D, E, H, and J.

32) Alignment complete.

Table 9.

   

SDS8486LN PointĆPoint Remote Alignment (Continued)

Summary of Contents for INTELIPORT I SDS5486LN

Page 1: ...28 and updates the company contact information Whenever this practice is updated the reason will be stated in this paragraph 1 3 Product Purpose and Description Westell s INTELIPORT I Model SDS5486LN...

Page 2: ...T monitors its transmission paths for in coming frequencies and interprets these frequencies as commands to carry out specific functions The command mode is activated from the STC by sending 2713Hz fo...

Page 3: ...T DATA DETECTOR SEALING CURRENT LB TEK5 TEK6 23 21 MICROPROCESSOR MLBG GND PWR 35 17 19 S1 SUPPLY OFF TERM LPBK AMP S3 A 2W 4W 1200 600 150 150 600 1200 DTT ALIGN LPBK TEST HYBRID XMT OUT LEVEL ADJUST...

Page 4: ...TELIPORT s intelligent functions which include XMT OUT Level Adjust mode remote alignment mode TLP or DLP Quiet Term Trans ponder mode or the STC can exit the command mode and return to idle NOTE The...

Page 5: ...ioning The ramp up tone also occurs whenever a 20 minute timer circuit times out due to inactivity that is no tone sent to INTELIPORT during a test function equipped with the 20 minute time out featur...

Page 6: ...and 3 14 above After obtaining the required XMT OUT level the STC must send 2713Hz for 0 9 seconds minimum to return to command mode 3 17 Quiet Term Transponder Operation INTELIPORT s Quiet Term Trans...

Page 7: ...pletion if no tone is sent during the 20 minute time frame INTELIPORT after 20 minutes sends a ramp up tone drops out of the Quiet Term Transponder mode and returns to idle If release is desired befor...

Page 8: ...the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines 5 1 Installer Connections When installing the unit in Westell s pre wired US...

Page 9: ...ndard test procedures for digital interface equipment using the KS 108 109 or equivalent re ceiver and transmitter data test sets This equipment should not be field repaired If the equipment is suspec...

Page 10: ...of 1014 Hz 414 Hz and enters loopback 4 Remote Manual Alignment Mode From command mode verify record level received at 1014 Hz then send 1004 Hz to INTELIPORT Upon detecting 1004 Hz INTELIPORT return...

Page 11: ...2222 Hz is detected and removed To add Loss Send and remove 2111 Hz INTELIPORT re adjusts output level by adding 0 5 dB of loss If more loss is required repeat the process of sending and removing 211...

Page 12: ...de send 1004 Hz 4 INTELIPORT returns 2814 Hz 5 Record level at 2814 Hz in Column B then send 2804 Hz 6 INTELIPORT returns 414 Hz 7 Record level at 414 Hz in Column B then send 404 Hz 8 INTELIPORT retu...

Page 13: ...All tones sent from STC are TLP unless stated otherwise TLP Transponder Mode 804 Hz Activated 1 While in command mode send 804 Hz 2 INTELIPORT applies quiet termination over the XMT IN port 3 STC perf...

Page 14: ...evel at the RCV demarcation point of Station A and Station Z STATION A SMAS SMAS STATION Z POINT B POINT C X X X X X X X X POINT A POINT D 5486LNI4 5486LNI4 OR EQUIVALENT 1 2 A B C D E F G H J A B C D...

Page 15: ...LP for 0 9 seconds minimum Station A returns to command mode 16 From SMAS Point A send 804 Hz at TLP When SMAS Point B goes quiet remove 804 Hz 17 Close SMAS access Point B to C 18 From SMAS Point D m...

Page 16: ...the warranty period for a nominal charge Contact Westell for details 9 SPECIFICATIONS 9 1 Ordering Specifications To order units call the telephone numbers shown in Paragraph 7 1 and please specify a...

Page 17: ...LP Transponder activated from command mode by sending 804Hz DLP Transponder activated from command mode by sending 1304Hz When activated INTELIPORT applies quiet termination and sets 20 minute timer c...

Page 18: ...MT OUT LEVEL TO 16dBm AFTER SETTING DESIRED XMT OUT LEVEL SEND 2713Hz FOR 0 9 SEC INTELIPORT RETURNS TO COMMAND MODE SEND 2713HZ FOR 0 9 SEC INTELIPORT RETURNS TO IDLE SEND 1804Hz START 3 TONE ALIGNME...

Reviews: