background image

Section SDSĆ548Ć6LNĆ204

030Ć101328 Rev. A

R

0208I4RA

16

7.

CUSTOMER & TECHNICAL SERVICES

7.1

Customer Service & Technical Assistance

If technical or customer assistance is required, contact Westell

by calling or using one of the following options:

Voice: (630) 898Ć2500

Voice: (800) 323Ć6883

email:

[email protected]

Visit the Westell World Wide Web site at http://

www.westell.com

for additional information about Westell.

7.2

Part Numbers

This Westell equipment is identified by a model number and an

issue level. Each time a change is made to the product which

changes the form, fit, or function of the product, the issue level/

letter is incremented or advanced by one. Be sure to indicate the

issue level as well as the model number when making inquiries

about the product.

8.

WARRANTY & REPAIRS

8.1

Warranty

Westell warrants this product to be free of defects at the time of

shipment. Westell also warrants this product to be fully funcĆ

tional for the time period specified by the terms and conditions

governing  the  sale  of  the  product.  Any  attempt  to  repair  or

modify the equipment by anyone other than an authorized WesĆ

tell representative will void the warranty.

8.2

Repair and Return

Westell will repair or replace any defective Westell equipment

without cost during the warranty period if the unit is defective

for  any  reason  other  than  abuse,  improper  use,  or  improper

installation. Before returning the defective equipment, first reĆ

quest a Return Material Authorization (RMA) number from

Westell. Once an RMA number is obtained, return the defective

unit, freight prepaid, along with a brief description of the probĆ

lem, to:

Westell, Inc.

ATTN: R.G.M. Department

750 N. Commons Drive

Aurora, IL 60504Ć7940

Replacements will be shipped in the fastest manner consistent

with the urgency of the situation. Westell will continue to repair

or replace faulty equipment beyond the warranty period for a

nominal charge. Contact Westell for details.

9.

SPECIFICATIONS

9.1

Ordering Specifications

To order units, call the telephone numbers shown in Paragraph

7.1,

 

and  please  specify  a  specific  model  number  shown  in

Table 10.

Part/Model #

Description & Comments

SDS5486LN

CLEI Code: DST1KDN1AA

 INTELIPORT LN" (Issue 4)

Technical Publication

030Ć101328

*CLEI is a trademark of Telcordia Technologies.

Table 10.    Ordering and Option Information

9.2

Electrical and Physical Specifications

The electrical and signaling specifications are listed below, and

the physical specifications for the SDS5486LN are shown are

shown in Table 11.

A.

RCV Level Range: Input, Ć10 to +5.0 dBm (TLP) or Ć23

to Ć8.0 dBm (DLP); Output, Ć3.0 dBm (TLP), Ć16.0 dBm.

B.

XMT Level Range: Input, +13 dBm (TLP) or 0 dBm

(DLP); Output, +5.0 dBm (TLP) or Ć8.0 dBm (DLP).

Ć NOTE Ć

XMT OUT level can be adjusted (in 0.5 dB gain/loss

increments)  for  any  level  from  +7.0  to  Ć16.0  dBm

(TLP) or Ć6.0 to Ć29 dBm (DLP)

C.

Impedance: FacilityĆside, selectable for 150, 600, 1200

Ohms via option switch S2; EquipmentĆside (2W/4W),

600 Ohms, fixed.

D.

Test Mode:  Activated by pressing frontĆpanel TEST

switch (<5 sec); Applies 1014 Hz to transmission ports

when activated (see Table 4); Equipped with automatic

release of one hour if switch not pressed a second time;

TEST switch can also be used to activate INTELIPORT's

AUTOĆALIGN feature by pressing switch for >5 sec and

only during first five minutes of initial powerĆup.

E.

Command Mode:  Activated by sending 2713 Hz (>30

sec). INTELIPORT returns 1014 Hz at +5dBm (TLP)

indicating command mode initiation. NOTE: If 2713 Hz

is removed in <30 sec, INTELIPORT sends alternating

1014 Hz/414 Hz tone and enters loopback.

F.

Equalization:  Automatically provides RCV channel amĆ

plitude equalization (up to 15dB, re: 1004 Hz) to meet

C5 conditioning.

G.

Remote Alignment:  Aligns to 3 or 4 tones, at TLP; ActiĆ

vated from command mode by sending 1004Hz in

response to INTELIPORT's 1014Hz (see para. 3.13

through 3.16 for details).

H.

AutoĆAlign:  Automatically aligns to 4 tones, at TLP; AcĆ

tivated by pressing the frontĆpanel TEST switch (>5 sec)

Summary of Contents for INTELIPORT I SDS5486LN

Page 1: ...28 and updates the company contact information Whenever this practice is updated the reason will be stated in this paragraph 1 3 Product Purpose and Description Westell s INTELIPORT I Model SDS5486LN...

Page 2: ...T monitors its transmission paths for in coming frequencies and interprets these frequencies as commands to carry out specific functions The command mode is activated from the STC by sending 2713Hz fo...

Page 3: ...T DATA DETECTOR SEALING CURRENT LB TEK5 TEK6 23 21 MICROPROCESSOR MLBG GND PWR 35 17 19 S1 SUPPLY OFF TERM LPBK AMP S3 A 2W 4W 1200 600 150 150 600 1200 DTT ALIGN LPBK TEST HYBRID XMT OUT LEVEL ADJUST...

Page 4: ...TELIPORT s intelligent functions which include XMT OUT Level Adjust mode remote alignment mode TLP or DLP Quiet Term Trans ponder mode or the STC can exit the command mode and return to idle NOTE The...

Page 5: ...ioning The ramp up tone also occurs whenever a 20 minute timer circuit times out due to inactivity that is no tone sent to INTELIPORT during a test function equipped with the 20 minute time out featur...

Page 6: ...and 3 14 above After obtaining the required XMT OUT level the STC must send 2713Hz for 0 9 seconds minimum to return to command mode 3 17 Quiet Term Transponder Operation INTELIPORT s Quiet Term Trans...

Page 7: ...pletion if no tone is sent during the 20 minute time frame INTELIPORT after 20 minutes sends a ramp up tone drops out of the Quiet Term Transponder mode and returns to idle If release is desired befor...

Page 8: ...the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines 5 1 Installer Connections When installing the unit in Westell s pre wired US...

Page 9: ...ndard test procedures for digital interface equipment using the KS 108 109 or equivalent re ceiver and transmitter data test sets This equipment should not be field repaired If the equipment is suspec...

Page 10: ...of 1014 Hz 414 Hz and enters loopback 4 Remote Manual Alignment Mode From command mode verify record level received at 1014 Hz then send 1004 Hz to INTELIPORT Upon detecting 1004 Hz INTELIPORT return...

Page 11: ...2222 Hz is detected and removed To add Loss Send and remove 2111 Hz INTELIPORT re adjusts output level by adding 0 5 dB of loss If more loss is required repeat the process of sending and removing 211...

Page 12: ...de send 1004 Hz 4 INTELIPORT returns 2814 Hz 5 Record level at 2814 Hz in Column B then send 2804 Hz 6 INTELIPORT returns 414 Hz 7 Record level at 414 Hz in Column B then send 404 Hz 8 INTELIPORT retu...

Page 13: ...All tones sent from STC are TLP unless stated otherwise TLP Transponder Mode 804 Hz Activated 1 While in command mode send 804 Hz 2 INTELIPORT applies quiet termination over the XMT IN port 3 STC perf...

Page 14: ...evel at the RCV demarcation point of Station A and Station Z STATION A SMAS SMAS STATION Z POINT B POINT C X X X X X X X X POINT A POINT D 5486LNI4 5486LNI4 OR EQUIVALENT 1 2 A B C D E F G H J A B C D...

Page 15: ...LP for 0 9 seconds minimum Station A returns to command mode 16 From SMAS Point A send 804 Hz at TLP When SMAS Point B goes quiet remove 804 Hz 17 Close SMAS access Point B to C 18 From SMAS Point D m...

Page 16: ...the warranty period for a nominal charge Contact Westell for details 9 SPECIFICATIONS 9 1 Ordering Specifications To order units call the telephone numbers shown in Paragraph 7 1 and please specify a...

Page 17: ...LP Transponder activated from command mode by sending 804Hz DLP Transponder activated from command mode by sending 1304Hz When activated INTELIPORT applies quiet termination and sets 20 minute timer c...

Page 18: ...MT OUT LEVEL TO 16dBm AFTER SETTING DESIRED XMT OUT LEVEL SEND 2713Hz FOR 0 9 SEC INTELIPORT RETURNS TO COMMAND MODE SEND 2713HZ FOR 0 9 SEC INTELIPORT RETURNS TO IDLE SEND 1804Hz START 3 TONE ALIGNME...

Reviews: