Section SDSĆ548Ć6LNĆ204
030Ć101328 Rev. A
R
0208I4RA
13
SDS5486LN OPTIONAL TESTS
XMT OUT LEVEL ADJUSTMENT
TO ADD GAIN
TO ADD LOSS
TO OBTAIN Ć16 dBm
TO ADD GAIN
TO ADD LOSS
TO OBTAIN Ć16 dBm
1.
From command mode, send 1704Hz
1.
From command mode, send 1704Hz
1.
From command mode, send 1704Hz
2.
INTELIPORT sends 1014 Hz at +5
dBm (TLP)
2.
INTELIPORT sends 1014 Hz at +5
dBm (TLP)
2.
INTELIPORT sends 1014 Hz at +5
dBm (TLP)
3.
STC sends and removes 2222 Hz
3.
STC sends and removes 2111 Hz
3.
STC sends and removes 2333 Hz
4.
INTELIPORT adds 0.5 dB of gain to
output level.
4.
INTELIPORT adds 0.5 dB of gain to
output level.
4.
INTELIPORT reĆadjusts output level
to Ć16 dBm (TLP).
5.
Repeat Steps 3 and 4 until desired
output level is obtained.
5.
Repeat Steps 3 and 4 until desired
output level is obtained.
5.
Send 2713 Hz for 0.9 seconds.
6.
Send 2713 Hz for 0.9 seconds
6.
Send 2713 Hz for 0.9 seconds
6.
INTELIPORT returns to command
mode
7.
INTELIPORT returns to command
mode
7.
INTELIPORT returns to command
mode
7.
Send 2713 Hz for 0.9 seconds.
8.
Send 2713 Hz for 0.9 seconds.
8.
Send 2713 Hz for 0.9 seconds
8.
INTELIPORT returns to idle.
9.
INTELIPORT returns to idle.
9.
INTELIPORT returns to idle
NOTE: Maximum output level is +7 dBm (TLP)
NOTE: Minimum output level is Ć16 dBm (TLP)
NOTE: Optional tests are initiated from command mode. All tones sent from STC are TLP unless stated otherwise.
TLP Transponder Mode (804) Hz Activated)
1)
While in command mode, send 804 Hz.
2)
INTELIPORT applies quiet termination over the XMT IN port.
3)
STC performs noise measurements at the RCV OUT port.
4)
STC sends any tone from 300 Hz to 3200 Hz (except 2700 Hz), in 100 Hz increments, at TLP.
5)
INTELIPORT returns similar tone (at a slight offĆset) for same duration tone is received, at +5 dBm (TLP or at the current XMT OUT
level established.
6)
Repeat Steps 4 and 5 as required.
7)
Upon completion and no other tone is sent by STC, INTELIPORT reapplies quiet termination and reĆsets 20Ćmin. timer.
8)
Send 2713 Hz for 0.9 seconds. INTELIPORT returns to command mode. Remove 2713 Hz.
9)
ReĆsend 2713 Hz for 0.9 seconds. INTELIPORT returns to idle.
DLP Transponder Mode (1304 Hz Activated)
1)
While in command mode, send 1304 Hz.
2)
INTELIPORT applies quiet termination at the XMT IN port.
3)
STC performs noise measurements at the XMT OUT port.
4)
STC sends any tone from 300 Hz to 3200 Hz (except 2700 Hz), in 100 Hz increments, at DLP.
5)
INTELIPORT returns similar tone for same duration tone is received, at Ć8 dBm (DLP) or at the current XMT OUT Level established.
6)
Repeat Steps 4 and 5 as required.
7)
Upon completion and no other tone is sent, INTELIPORT reapplies quiet termination and reĆsets 20ĆMin. timer.
8)
Send 2713 Hz for 0.9 seconds. INTELIPORT returns to command mode. Remove 2713 Hz.
9)
ReĆsend 2713 Hz for 0.9 seconds. INTELIPORT returns to idle.
Table 8. SDS5486LN Optional Tests