1.10 REQUIREMENTS FOR STANDARD e/o ATEX INSTALLATION
The hydromechanic coupling is a partly completed machine exclusively designed
for use in industrial environments and its installation must be in compliance with the
following requirements:
- indoor use in a protected location/room,
- ambient temperature between –20°C and +60°C (suitable types of oil must
be used),
- atmosphere of the operating zone void of corrosive or acid mists
- plant including a coupling equipped with a safety device TF (Fusible Plug) and
provided with both protection guards and fluid collection containers, should the
fluid leak due to overheating,
- mandatory use of appropriate biologic mineral oil to safeguard the environment
- installation room provided with interlocked protections, which prevent any
access when voltage is supplied,
- suitable room layout to prevent objects from falling or any access to the
coupling during operation,
- installation location far from intense vibration sources,
- installation location far from heat irradiation, hot air streams or electrostatically
charged air,
- easily accessible location for safe maintenance works,
- installation in potentially explosive atmospheres, where methane concentration
is lower than 1%.
- correct identification of
• enviorment:
I mining / II surfaces ind.
• category:
M2 mining / 2 surfaces ind.
• Epl Protection Level Mb mining: Gb/Db surface industries
• Gas Group Ignition:
IIB /IIC
CAUTION
This handbook must be forwarded to the final user of the machine
or partly completed machine, where the hydromechanic coupling will be
incorporated, because it provides information for its safe use and correct
maintenance schedule.
The installation of the ROTOMEC constant-fill hydromechanic coupling must be
compliant with the data reported on the identification plate, the manufacturer’s
instructions in the TECHNICAL DATA SHEET and in this Use, Maintenance and
Installation Handbook. For use in environment with characteristics different from
what pointed out above, please call the WESTCAR Technical Department.
CAUTION
Should oil leak after intervention of the fusible plug (TF), it is
mandatory to stop the motor as soon as possible; RISK OF OVERHEATING
of non lubricated bearings and gasket seals.
- When using a coupling in over see machines, it is required to stop the motor
within 3 min.
- When using a coupling in machines without operator, it is required to install
an automatic shutdown device to immediately stop the engine.