36
Decals, Numbers and Logos
1. Place a ceiling operation decal near each ceiling stay approximately 2" (51 mm) from the upstage edge.
Final Inspection
1. Check the rigging.
a. Make sure that it operates smoothly and safely.
b. Determine if additional weights need to be added to any arbors to offset
the additional weight of ceiling stays, lights, etc.
2. Make sure that all cable clamps are not missing any hardware.
3. Inspect all ceiling panels for surface finish damage.
Touch up as required.
4. Place a Warning decal near each ceiling stay approximately 2" (51 mm) from the upstage edge.
5. Make sure that all wiring for lighting is tied away from the light canisters and that the wiring does not
interfere with ceiling panel row rotation.
6. Discuss the preferred light focus with the general contractor or the site’s lighting technician.
Schematics
Lieto LED Light Fixture Electrical Schematic (Diva
®
Acoustical Ceiling)
LED SCHEMATIC FOR WENGER
MANUALS
& ES51089
8.50
11.00
L1
L2
L3
L4
JUNC
TION BO
X
RED
TILT SWITCH
110/240
VAC
JUNC
TION BO
X
N1
N2
N3
CIRCUIT 1
LN
G
LN
G
LN
G
LN
G
LAMP 1
LAMP 2
LAMP 31
LAMP 32
LAMP 40
CIRCUIT 2
CIRCUIT 3
CIRCUIT 4
LAMP 21
LAMP 11
LAMP 22
LAMP 12
LAMP 30
LAMP 20
LAMP 10
N4
RED
L NG
L NG
L NG
L NG
RELAY
NEUTRAL TERMINAL BLOCK
GROUND BAR
HOUSE POWER SUPPLIED
IN FIELD BY OTHERS
CIR
CUIT 4
CIR
CUIT 3
CIR
CUIT 2
CIR
CUIT 1
RA
CE
W
AY
See applications
documents for
coil voltage