Wenger Diva Installation Instructions Manual Download Page 12

12

Ceiling Installation (continued)

Attach the Hanger Arms to the Truss Assembly

1.  Attach the hanger assemblies to the ceiling truss.

a.  Remove a hanger assembly from the hanger kit hardware bag.
b.  Unscrew the two lock nuts and remove the carriage bolt and the hex head screw.  

Save the hanger straps, lock nuts, carriage bolt, and screw.

Be sure that the hanger assemblies 

cannot slip off of the ceiling truss.

Hanger Assembly Strap

Carriage Bolt

Hex Head Screw

Lock Nut

Hanger Assembly

Truss

Hanger 

Assembly

Carriage 

Bolt

Lock Nut

Truss 

Assembly

Hanger 

Arm

Batten

Lift Line

Hanger 

Assembly

Head of Carriage Bolt 

must be on downstage 

side of truss.

c.  With the ceiling truss centered below the batten, attach a hanger assembly to the truss by fitting the 

 

two hanger assembly straps onto the truss as shown below.  

Attach the carriage bolt and a lock nut set aside in step 1b finger tight.

d.  Slide the hanger assembly on the truss so that it aligns to a hanger arm.  

Tighten the lock nut with a 3/4" combination wrench.

e.  Assemble additional hanger assemblies below each hanger arm by repeating steps 1a to 1d.

!

CAUTION

Summary of Contents for Diva

Page 1: ... Connection 31 Lieto LED Light Fixture Communication 31 DMX Address Information 32 LED Power Settings Chart 32 Troubleshooting 32 Light Fixture Operation 32 Adjustment and Aiming 32 Photometrics 33 Schematics 36 Lieto LED Light Fixture Electrical Schematic Diva Acoustical Ceiling 36 Decals Numbers and Logos 36 Final Inspection 36 Installation Instructions Diva Acoustical Ceiling Wenger Corporation...

Page 2: ...ct at any time The information in this document is not intended to cover all possible conditions and situations that might occur The end user must exercise caution and common sense when assembling or installing Wenger Corporation products If any questions or problems arise call the Wenger Corporation at 800 4WENGER 493 6437 or 1 507 455 4100 worldwide Manufacturer The Diva Acoustical Ceiling is ma...

Page 3: ... follow the instruction could result in minor injury or damage to property Read all of these safety instructions before using the equipment Save the wood blocks from the tower frame and ceiling truss packaging They will later be used during the tower assembly The following tools are required for assembly Assorted wrenches Cordless drill and cordless impact driver 3 8 1 2 and 9 16 hex nut bit Rubbe...

Page 4: ...ill 1 4 14 x 3 4 Hex Head Screw 3 8 16 x 3 1 2 Lock Nut 1 4 20 Lock Nut 1 2 13 Lock Nut 3 8 16 Hex nut 5 16 18 Tapping Screw 5 6 x 1 Carriage Bolt 1 2 13 x 4 Screw Pan Head 10 24 x 5 8 Screw Self drill 1 4 20 x 1 1 4 Hex Jam Nut 1 8 Hex Head Screw 3 8 16 x 2 1 4 Tapping Screw 1 4 20 x 1 2 Screw Sheet Metal 10 18 x 3 4 Hex Head Screw 1 2 13 x 2 Screw Self drill 1 4 20 x 1 Rivet Blind Tri Fold 0 19 ...

Page 5: ...eiling assembly Hanger Arm Assembly Connects the ceiling assembly to the stage rigging Truss Assembly Structural component that also serves as an electrical raceway Ceiling Panel Provides the sound reflective surface for the ceiling assembly Bowstring Structural component used to suspend the ceiling panel when in the performance position ...

Page 6: ...ility owner Make sure that all rigging and rigging hardware is capable of lifting the calculated weight of the ceiling assemblies Components can be heavy or difficult to handle and may require three or more people working together to lift or assemble Personnel must always wear a safety harness when working above the floor surface 1 Read and understand the entire ceiling installation section before...

Page 7: ...er tight until all screws are installed c When all screws are installed and the trusses are aligned tighten all screws d Make sure that the truss caps are installed 2 Find and mark the center location of the truss assembly Ceiling Installation Always refer to the installation drawings for the location and arrangement of ceiling panels STOP Truss Splice Bar Self drilling Screw 1 4 14 x 3 4 Truss Sp...

Page 8: ... line between the mid points marked upstage and downstage Downstage Upstage Stage Left Stage Right Measure an Equal Distance Measure an Equal Distance Strike a Chalk Line on the Stage Centerline marked from the intersection of the two measurements Proscenium Opening Measure an Equal Distance Measure an Equal Distance Batten Mark the Stage Centerline position on the Batten using the Plumb Line Batt...

Page 9: ...s follows a Remove a turnbuckle assembly with attached pipe clamp from the hanger kit hardware bag b Remove the lock nut hex head screw or the cotter key cross pin that attach the pipe clamp to the turnbuckle upper jaw Save this hardware for reattachment c Adjust the turnbuckle to a position midway between the upper jaw and the lower jaw Ceiling Installation continued Pipe Clamp Turnbuckle Assembl...

Page 10: ...to secure cotter key f Attach other turnbuckle assemblies to the batten by repeating steps 2a to 2e Batten Batten Pipe Clamp Turnbuckle Assembly Turnbuckle Assembly Lift Lines Batten Lift Line Batten Pipe Clamp Pipe Clamp Pipe Clamp Attach the Hanger Arms to the Batten continued 2 continued d At the proper locations attach the pipe clamp to the batten using two hex head screws and tighten securely...

Page 11: ...the turnbuckle lower jaw and re attach the lock nut and screw set aside in step 3a with a pair of 9 16 combination wrenches Refer to the illustration below Align the hanger arms as shown on the installation drawings c Attach other hanger arms to the turnbuckle assemblies by repeating steps 3a and 3b Batten Lift Lines Turnbuckle Hanger Arm Hanger Arm Upper Eye Lock Nut and Screw Turnbuckle Batten N...

Page 12: ...rew Lock Nut Hanger Assembly Truss Hanger Assembly Carriage Bolt Lock Nut Truss Assembly Hanger Arm Batten Lift Line Hanger Assembly Head of Carriage Bolt must be on downstage side of truss c With the ceiling truss centered below the batten attach a hanger assembly to the truss by fitting the two hanger assembly straps onto the truss as shown below Attach the carriage bolt and a lock nut set aside...

Page 13: ... to a hanger assembly with the hex head screw and lock nut set aside in step 1b on the previous page Tighten with a pair of 3 4 combination wrenches c Attach the other hanger arms to the ceiling panel row by repeating steps 2a and 2b d Adjust the turnbuckles so that there is equal tension on each hanger arm e Using a pair of 3 4 combination wrenches tighten all of the lock nuts and screws 3 Raise ...

Page 14: ...ce between each panel as shown below Ceiling Panel 4 x 8 Sheets of Packing Material Approximately 4 of spacing Batten Lift Line Foam Strip Ceiling Panel Recess Ceiling Panel Ceiling Panel Insert a Foam Strip into one Recess between two Ceiling Panels being joined together Downstage Edge Orient panels so part number labels are on Stage Right 2 Where two ceiling panels join together insert a foam st...

Page 15: ...g c Attach a 1 4 20 x 3 1 2 carriage bolt and 1 4 20 hex nut on the opposite side of the panels by repeating steps 3a and 3b d With two people working together use 7 16 sockets with universals and tighten the hex nuts keep the tension equal on both sides by tightening each side at the same time until the two panel inner corner clips begin to bend Carriage Bolt 1 4 20 x 3 1 2 Hex Nut 1 4 20 Panel O...

Page 16: ...bly to the ceiling panel row Ceiling Panel Joint Note Install a hanger bracket above each seam at these points Hanger Bracket Assembly Truss Assembly Truss Hanger Bracket Slot Hanger Bracket Leg Hanger Bracket Assembly Jack Tube Bearing Bearing Upstage Side Note Hanger bracket assemblies are preassembled and a jack tube may not be required Follow the installation drawings b Insert a hanger bracket...

Page 17: ... Bracket Leg Ceiling Panel Center Channel Note The hanger bracket must be pressed downward until it is flush with the top of the ceiling panel center channel legs Truss Assembly Hanger Bracket Assembly Self drilling Screws 1 4 14 x 3 4 Self drilling Screws 1 4 14 x 3 4 Upstage Upstage 3 Attach the hanger bracket assemblies to the truss assembly a Use a cordless drill and a 9 16 hex nut bit b Screw...

Page 18: ...ck to the bowstring as shown in the illustration below b Slide a ceiling clip onto each end of the bowstring The ceiling clip flanges must face to the inside or each other Short Bowstring Ceiling Clip Short Bowstring Ceiling Clip Short Bowstring Hex Head Screw 3 8 16 x 2 1 4 Lock Nut 3 8 16 Bowstring Jack Ceiling Clip Flange Hex Jam Nut 1 8 Bowstring Jack Hanger Bracket Jack Tube c Place the bowst...

Page 19: ... the rear flange of the ceiling panel extrusion drilled in step 3 Do not over tighten the screw Note If the tapping screw is over tightened and strips the thread fasten a 9 32 nut to the screw 5 Using a cordless drill and a 3 8 hex drive bit screw two self drill screws through the two ceiling clip bowstring mounting holes in each ceiling clip into the bowstring Do not over tighten the screw Ceilin...

Page 20: ...he jack tube 3 Use a 1 1 2 open end wrench and turn the jam nut an addition full turn clockwise six flats 4 Repeat steps 1 through 3 above on all of the other bowstrings Bowstring Hex Jam Nut 1 8 Jack Tube Note Turn the jam nut clockwise until it is snug against the jack tube Then turn the jam nut an additional full turn clockwise six flats Do not load weights onto the Arbor until tension is appli...

Page 21: ...to the ceiling stay mounting hole in the truss assembly Always assemble the ceiling stay on the upstage side refer to the illustration below b Insert the hex head screw removed in step 1 through the base bracket mounting hole and the ceiling stay mounting hole in the truss and attach the washer and lock nut set aside in step 1 above to the screw as shown in the illustration below c Use a 9 16 comb...

Page 22: ...ay end bracket mounting hole and rear flange of the panel extrusion as shown below Do not over tighten the screw c Use four 0 19 dia tri fold blind rivets through the four mounting holes into the ceiling panel as shown below Ceiling Installation continued Ceiling Stay Assembly Ceiling Panel Note Place the ceiling stay end bracket flush with the edge of the ceiling panel Tri Fold Blind Rivet 0 19 D...

Page 23: ...he ceiling panels from the stage surface and apply about 100 lb 45 kg of tension to each lead set cable to set each cable 5 Keeping the ceiling assembly horizontal lift it 4 to 5 1219 to 1524 mm from the floor Typical Rigging System Arrangement Ceiling Panel Row Batten Arbor with Weights Floor Only qualified personnel who are familiar with rigging systems should set up the rigging add weights to t...

Page 24: ...s follows a Rotate the ceiling panel row so that the bottom surface faces downstage b Then rotate the ceiling panel row so that the bottom surface faces upstage c Any ceiling panel row bowing in either vertical position indicates that further leveling is required 4 When leveling is complete lock the turnbuckles into place with nylon cable ties contained in the hanger kit hardware bag 5 Make sure t...

Page 25: ...on 2 Use a pair of 7 16 combination wrenches to loosen finger tight all of the hex head screws four and lock nuts on the latch receiver assembly 3 Slide the latch receiver assembly away from the ceiling stay latch Do not tighten the screws Hanger Arm Latch Receiver Assembly Hex Head Screw Ceiling Stay Rod Ceiling Stay Rod Note Ceiling Panel Row is shown in the Storage Position Ceiling Stay Latch L...

Page 26: ...e receiver engages the ceiling stay latch 6 Use a pair of 7 16 combination wrenches and tighten all of the hex head screws four and lock nuts on the latch receiver assembly 7 Check the performance angel and make any necessary adjustments Performance Angle Ceiling Stay Rod Ceiling Panel Row Ceiling Stay Receiver Ceiling Stay Lever Slide the Ceiling Stay Receiver toward the Ceiling Stay Latch until ...

Page 27: ... bolt and lock nuts aside Ceiling Catch Pivot Plate U bolt Lock Nut Ceiling Catch Assembly Ceiling Panel Row Hanger Arm U bolt Ceiling Catch Assembly 3 Using the installation drawings as a reference place the ceiling catch assembly into the place on a hanger arm 4 Attach the ceiling catch assembly to the hanger arm with the u bolt and two lock nuts set aside in step 2 above Tighten the lock nuts w...

Page 28: ...Each ceiling panel light must connect to a grounded three wire receptacle that connects to a fused circuit breaker This procedure details installing the Lieto LED Light Fixture If installing other light fixtures contact Wenger STOP WARNING 1 Insert the light fixture into the pre cut ceiling panel light mounting hole 2 Attach the light assembly to the ceiling panel a Use a 13 64 bit to drill a pilo...

Page 29: ...range of 100 240VAC 50 60Hz 4 Power up the light fixture to ensure proper connections Do not connect or disconnect the LED PowerCON connector under load CAUTION 5 Insert the safety cable through the eye bolt on the light box assembly then secure the other end of the safety cable to the truss assembly Lieto LED Light Fixture Electrical Connection Daisy Chain Multiple LED Lights Row Mounted Junction...

Page 30: ... micro USB port next to the power lock button 6 Select the Wenger app on the tablet home screen 7 Once the app is open running the diagnostic information window for the currently connected light fixture is displayed view the information and select ok 8 If a change to any of the fields is necessary select the field enter the new value the select set The adjustable fields are Device Label ex Wenger ...

Page 31: ... device will continuously illuminate green once the connection is established 8 Configure the fixture to the required DMX RDM address based on the site s requirements 9 If required select and hold down the Link icon in the lower left corner of the screen to disconnect the DMXcat device from the configuration tablet Wait for the LED status indicator to flash four times before disconnecting the devi...

Page 32: ... of tooling could cause damage CAUTION DMX Address Information The Lieto White Fixture requires 1 DMX Channel The Lieto Color Fixture requires 4 DMX Channels Channel 1 Intensity 0 255 Channel 1 Red 0 255 Channel 2 Green 0 255 Channel 3 Blue 0 255 Channel 4 White 0 255 Light Fixture Configuration continued Adjustment Knobs Troubleshooting The Lieto LED light fixture will default to Full On when the...

Page 33: ...106 5 106 0 111 4 114 3 108 5 100 1 94 5 109 7 117 5 87 4 119 4 120 0 104 0 108 5 118 1 121 3 117 3 111 7 111 6 115 7 118 2 118 7 117 1 112 9 112 4 117 4 121 1 116 9 107 4 104 4 118 5 118 9 113 7 118 8 104 5 107 0 116 4 119 1 115 4 111 2 110 6 113 1 114 8 115 6 114 4 111 6 111 3 115 1 118 8 114 9 106 9 108 9 125 2 113 0 112 0 119 0 106 6 104 0 109 5 113 7 112 6 109 5 108 0 107 0 106 4 107 2 108 3 ...

Page 34: ...xture Operation continued Photometrics continued REV Page 2 of 3 PROJECT DESCRIPTION SIZE B DWG NO NAME DATE PHOTOMETRIC 1 WENGER ORDER NUMBER CHECKED DRAWN ACCOUNT NAME CITY STATE 19PXXXXX_PM CJB 12 10 19 16XXXXX ...

Page 35: ... 75 12X40 45 75 12X40 30 150 36 150 70 150 70 125 12X40 125 28 125 28 FA FA 125 12X40 125 28 REV Page 3 of 3 PROJECT DESCRIPTION SIZE B DWG NO NAME DATE PHOTOMETRIC 1 WENGER ORDER NUMBER CHECKED DRAWN ACCOUNT NAME CITY STATE 19PXXXXX_PM CJB 12 10 19 16XXXXX NOTES 1 LIGHT FIXTURES NOT INDICATED BY FA TO BE ADJUSTED PERPENDICULAR TO THE STAGE FLOOR 2 LIGHT FIXTURES INDICATED BY FA WILL REQUIRE FIELD...

Page 36: ...t all wiring for lighting is tied away from the light canisters and that the wiring does not interfere with ceiling panel row rotation 6 Discuss the preferred light focus with the general contractor or the site s lighting technician Schematics Lieto LED Light Fixture Electrical Schematic Diva Acoustical Ceiling LED SCHEMATIC FOR WENGER MANUALS ES51089 8 50 11 00 L1 L2 L3 L4 JUNCTION BOX RED TILT S...