23
Ceiling Installation (continued)
Fly The Ceiling Assembly
1. Clean all debris from the ceiling panels and remove any tools resting on the ceiling panels.
2. Get the weight of the ceiling assembly and the arbor weight calculation from the installation drawings.
3. Start adding the weights to the arbor.
a. Three or more persons should work together, one person adding weights and one person tending
to the line to see if the ceiling assembly can be lifted from the floor.
b. Check the ceiling assembly counter balance early and often
(after adding each increment of one hundred pounds).
4. Using the rigging system, lift the ceiling panels from the stage
surface and apply about 100 lb (45 kg) of tension to each
lead-set cable (to set each cable).
5. Keeping the ceiling assembly horizontal,
lift it 4' to 5' (1219 to 1524 mm) from the floor.
Typical Rigging
System Arrangement
Ceiling Panel
Row
Batten
Arbor with
Weights
Floor
Only qualified personnel who are
familiar with rigging systems should
set up the rigging, add weights to
the arbor, or fly the ceiling panels.
Make sure that all rigging and rigging hardware
is capable of lifting the ceiling panel component
calculated weight plus a reasonable margin of safety.
Always comply with local codes and regulations.
Make sure that all fasteners
are tight before adding any
weight to the arbor.
Never climb on the ceiling
panels.
!
WARNING
!
WARNING
!
WARNING
!
WARNING
4' to 5'
(1219 to 1524 mm)
from floor