Debug Settings:
WellGate 2522 provides the real time debug to syslog or through telnet
interface. It generates the debug information based on debug level and
modules. Since the generating debug will consume system resources, it is
recommended to turn on only for necessary and under Welltech FAE’s
instruction.
Debug
Parameter Description:
Syslog:
Enable or disable to send system information to syslog server or
not
Check for start from Any Time:
Always Send: Always send syslog or
only during a specified time range.
Syslog Start (YYYY/MM/DD HH:MM):
Always Send: Always send
syslog or only during a specified time range.
Syslog Stop (YYYY/MM/DD HH:MM):
The syslog stop sending time.
Syslog Server:
Syslog server IP address
Syslog Port:
Syslog server service port (default is 514)
DSP Debug:
Enable or disable to send DSP information to capture log
DSP Capture server:
syslog capture server IP address
DSP Capture port:
syslog capture server service port (default is 50000)