![background image](http://html.mh-extra.com/html/welbilt/garland-me-1p/garland-me-1p_troubleshooting-manual_953801008.webp)
Part Number: 4604223 — Rev:0
9
Section 1
Section 1
LED
Color
Name
Meaning
1
Green
3.3V Power
Constant when power supply connected
3
Green
Motor Up
Lights while platen motor moving up
4
Blue
Motor Down
Lights while platen motor moving down
5
Red
PWR SYNCH
Blinks when high voltage detected from SSRB
6
Red
DEBUG 1
Data Communication: On during normal operation
7
Red
DEBUG 2
Data Communication: Blinks during normal operation
8
Red
DEBUG 3
Data Communication: Blinks rapidly during normal operation
9
Red
DEBUG 4
Data Communication: Blinks when SIB software updates, lights if error between SIB and UI
10
Green
Heartbeat
Blinks during normal operation
11
Green
5V Power
Constant when power supply connected
12
Green
12V Power
Constant when power supply connected
14
Blue
Green Button
Light when green button is pressed
(The right most LED at location indicated).
17
Amber
Upper / Lift
On until platen is at the upper switch (or higher)
18
Amber
Home
On until platen is at the home switch (or lower)
21
Green
24V Power
Constant when power supply connected
27
Orange
Over Current
Blinks momentarily during boot and if motor goes over current
SIB Board - LED Location