Error code
Error description
Required response
E01
Not enough water: Water pressure lower
than 0.5 bar five seconds after valve is
opened
■
Open the water connection valve
■
Contact Customer Service
E02
Excessively high temperature in electrical
wiring compartment
■
Clean the lint screen at the back of
the unit
■
Make sure that the air intake is not
being obstructed at the back of the
unit
■
Contact Customer Service
E03
Fan fault / Motor TP (thermostat) has trip‐
ped or variable frequency drive fault
■
Check the fuse/circuit breaker in the
building's load center
■
Contact Customer Service
E04
Electrical wiring compartment auxiliary
fan fault
■
Clean the lint screen at the back of
the unit
■
Make sure that the air intake is not
being obstructed at the back of the
unit
■
Contact Customer Service
E11
Oven sensor (B6) has detected an ex‐
cessively high temperature
Contact Customer Service
E15
Condenser sensor (B3) has detected an
excessively high temperature
■
Open the water connection valve
■
Contact Customer Service
E16
Dehumidifier valve fault: Dehumidifier
valve cannot be initialized
■
Restart the unit
■
Contact Customer Service
E21
Oven sensor (B6) discontinuity
Contact Customer Service
E22
Core temperature probe (B10) disconti‐
nuity
Contact Customer Service
E25
Condenser sensor (B3) discontinuity
Contact Customer Service
E29
Core temperature probe (B10) has a
short circuit to frame
Contact Customer Service
E80
ID error:
The unit does not recognize the heating
method
Contact Customer Service
E81
Cooking profile not saved correctly
■
Write the cooking profile again
■
Import the cooking profile backed up
on the IDM
■
Contact Customer Service
E83
Impermissible cooking algorithm
■
Rewrite the cooking program
■
Contact Customer Service
E96
Communication error between SM and
BM
■
Disconnect the unit from the outlet
for approx. 10 seconds and restart it
■
Contact Customer Service
E97
Error message cannot be output
Contact Customer Service
None
IDM error (IDM = Identification module)
■
Turn off the unit and then turn it back
on
■
If the error continues to be displayed:
Contact Customer Service
None
Fatal IDM error (IDM = Identification
module)
Contact Customer Service
6 How to Perform Maintenance on the Combi Oven
Operating Manual
71