38
E16.0
Dehumidifier valve fault: Dehumidifier
valve cannot be initialized
■
Restart the unit
■
Contact Customer Service
47
E83.0
Impermissible cooking algorithm
■
Rewrite the cooking program
■
Contact Customer Service
48
_
Invalid data in identification module (IDM)
■
Disconnect the unit from the outlet
for approx. 10 seconds and restart it
■
Contact Customer Service
49
_
Error text cannot be loaded
■
Turn off the unit and then turn it
back on
■
Contact Customer Service
72
E03.0
Fan fault / Motor TP (thermostat) has trip‐
ped or variable frequency drive fault
■
Check the fuse/circuit breaker in the
building's load center
■
Contact Customer Service
6.2.2 Emergency Mode
Running the combi oven in emergency mode
The combi oven features an emergency mode in order to allow you to keep using it if there is an error
or fault that cannot be fixed right away.
This mode will let you keep running the unit (with a number of limitations) even when there is a mal‐
function.
Always notify Customer Service!
Prerequisites
■
The unit is malfunctioning.
■
An acoustic signal is emitted.
■
An error code is shown on the display.
Running the unit in emergency mode
1.
Confirm the error being displayed and start a cooking or
cleaning profile that uses an available operating mode.
Limitations
■
Cooking times may be longer and cooking results may be uneven. Because of this, pay special at‐
tention to the cooking sequence and to how well-cooked your product is.
■
The unit may need to use more water than usual.
■
Fully automatic and semi-automatic cleaning may not be available or may only be possible to a
limited extent.
■
It may not be possible to use the core temperature probe and the optional sous vide probe in cer‐
tain cases.
■
The only functions available will be those not affected by the fault, error, or malfunction that has
occurred.
6 How to Perform Maintenance on the Combi Oven
Operating Manual
73