Errors and required responses (easyTouch)
The following table lists the errors that you will be able to fix yourself under certain circumstances. If
the combi oven keeps showing the error even after you attempt to fix it, contact Customer Service.
If any error messages other than the ones listed here appear, contact Customer Service.
Fault
ID
Refer‐
ence
Error description
Required response
3
E25.0
Condenser sensor (B3) discontinuity
Contact Customer Service
5
E21.0
Oven sensor (B6) discontinuity
Contact Customer Service
6
E22.1
Core temperature probe (B10) discontinui‐
ty
Contact Customer Service
7
E22.2
8
E22.3
9
E22.4
12
E25.1
Condenser sensor (B3) has a short circuit
to frame
Contact Customer Service
14
E21.1
Oven sensor (B6) has a short circuit to
frame
Contact Customer Service
15
E29.1
Core temperature probe (B10) has a short
circuit to frame
Contact Customer Service
16
E29.2
17
E29.3
18
E29.4
21
E15.0
Condenser sensor (B3) has detected an
excessively high temperature
■
Open the water connection valve
■
Contact Customer Service
23
E11.0
Oven sensor (B6) has detected an exces‐
sively high temperature
Contact Customer Service
24
E02.0
Excessively high temperature in electrical
wiring compartment
■
Clean the lint screen at the back of
the unit
■
Make sure that the air intake is not
being obstructed at the back of the
unit
■
Contact Customer Service
25
E12.1
Core temperature probe (B10) has detec‐
ted an excessively high temperature
Correct probe position
26
E12.2
27
E12.3
28
E12.4
29
E03.0
Fan fault / Motor TP (thermostat) has trip‐
ped or variable frequency drive fault
■
Check the fuse/circuit breaker in the
building's load center
■
Contact Customer Service
30
E96.0
Communication error between SM and BM
■
Disconnect the unit from the outlet
for approx. 10 seconds and restart it
■
Contact Customer Service
31
E99.0
Communication interface malfunction
Disconnect the unit from the outlet for
approx. 10 seconds and restart it
32
E99.9
General initialization error
33
E01.0
Not enough water: Water pressure lower
than 0.5 bar five seconds after valve is
opened
■
Open the water connection valve
■
Contact Customer Service
36
E04.0
Electrical wiring compartment auxiliary fan
fault
■
Clean the lint screen at the back of
the unit
■
Make sure that the air intake is not
being obstructed at the back of the
unit
■
Contact Customer Service
6 How to Perform Maintenance on the Combi Oven
Operating Manual
72