Safety measures
The following measures will contribute to greater safety:
Measure
Function
Check
Unit door solenoid
switch (electrical door
sensor)
■
Stops/turns off the following when
the unit door is opened:
■
Fan (will stop after a few sec‐
onds)
■
Heating element
■
Cleaning agent spraying in the
fully automatic oven cleaning
process
■
Prompts the user to close the unit
door
Test the door solenoid switch with
the combi oven at a low temperature
Procedure:
■
Fully open the unit door
■
Press Start
Result:
The motor must not start running.
Unit door handle with
cracked-open position
■
Prevents steam coming out from
scalding the operator's face and
hands
With the combi oven at a low tem‐
perature, check the door positions
as described in 'Safely Opening and
Closing the Unit Door' on page 38
in the operating manual
Resuming after a power
outage if there was
cleaning agent inside
the unit when the power
went out
■
Starts the fully automatic oven
cleaning process again, from a de‐
fined state, after a power outage
None
3 For Your Safety
Operating Manual
30