13
2.
Never connect the MINI to HOT WATER! The condenser system will not work properly if
connected to HOT or WARM water.
3.
The water supply must have a minimum dynamic (flow) pressure of 35 psi (2.4 kg/cm²)
and a maximum static pressure of 80 psi (4.1 kg/cm²).
4.
If the static pressure is above 80 psi, a pressure regulator must be used and set at
approximately 50 psi. Pressure above 80 psi can damage solenoid valves.
5.
MINIs have two connection points for incoming water. See Figure in section 4 on page 11.
6.
Water supply must meet the minimum requirements shown in the Warranty and Table 2-
3. Install a water treatment system as needed.
7.
Installation Requirements:
a.
Apply non-hardening pipe thread sealant to all the threaded connections
except
the
¾” GHT Female (Garden Hose Thread or National Hose Thread) connections at the
Water Connection. GHT or NHT connections do not require pipe thread sealant.
b.
Install a manual water shut-off valve (not provided) between main water supply lines
and MINI supply lines.
c.
This may require the installation of a check-valve (or other approved anti-backflow /
anti-siphon device) (not provided) in all supply lines in accordance with and as
required by local, state, and national health, sanitation and plumbing codes.
d.
Check local codes to determine exactly what type of anti-backflow / anti-siphon device
is necessary to meet local requirements.
2.4.5
Included water connection and drain kit parts
Kit Part # 8104877
Item
ID#
Description
Qty
1
24258
3/4" FEMALE HOSE X 3/4" MALE HOSE LEAD FREE
2
2
24259
1 1/2" X 1 1/4" RUBBER COUPLING
1
Item #1 – Connect to the two (2) hose connections on the rear of the oven.
Item #2 – Connect to the stainless steel tube that is exiting the rear of the oven.
Item #1