7
2.3.3
Installation of a Convotherm Hood
1.
Carefully unpack the unit and place in an open work area.
2.
Remove protective plastic covering.
3.
Remove top access panel to retrieve heat exchange connection hose and DB-9 cord.
4.
Replace top access panel.
5.
Remove back access panel and the side access panel (see Figure 1).
6.
Guide the vent tubes on the oven up through the
grommets (see Figure 2).
7.
Locate the blue hose, hose clamps and data cable in
the top access panel, included with the hood (see
Figure 3).
8.
Attach the hose to the vent connection towards the
front of the oven (see Figure 4) and secure with hose
clamp.
9.
Ensure the heat exchanger is resting on its shelf. It
may have shifted during shipping or handling of the
box (see Figure 5).
Figure 2
Figure 1
Figure 5
Figure 3
Figure 4