Product Manual
Aqua Logic (CWH) Performance Mode quick set-up
3EEPAGEFORPERFORMANCERATINGSAT()'(0%2&/2-!.#%./2-!,AND%#/./-9
-ODE
$ESCRIPTION
OFF-DISABLED
Contractor-selected — Aqua Logic (CWH) operation is disabled; can only be activated by a contractor
User-selected — Aqua Logic (CWH) operation turned off; can be turned on by user in the Performance Mode
Menu
When performance mode is set to OFF-DISABLED, no freeze protection is provided in control
operation. In other performance modes, the WM97+ control will always maintain a minimum
temperature to reduce possibility of freeze-up.
HIGH
PERFORMANCE
Delivers the highest performance available and maximizes the energy of the stored water for demanding
applications. Use during peak-demand periods when multiple fixtures will be running.
NORMAL
A balance of performance and efficiency. Delivers hot water for a shower, sinks, or faucets continually (except
WM97+70 model). General setting for most times of the day.
ECONOMY
Saves energy by operating with lower boiler temperatures and storing tank at lower temperature for lowest standby
losses. Not recommended for showering with 70°F temperature rise. Ideal setting in schedule mode for low-use
periods.
VACATION
Maintains tank temperature above 50°F to deter freezing in tank. This mode will not supply hot water to the user.
SCHEDULED
This mode allows programming up to 4 different performance modes to occur at different times of the day. There
are different schedules for Weekdays (M-F) and Weekends. This allows energy savings by keeping the tank at low
temperatures when not needed and meeting peak demands during times of typical high usage. These times must
be programmed by the contractor or user.
Part number 635-500-156/1113