上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD
27
/
53
N74100 Lead Screw Pitch
It refers to the axial distance or degree between the corresponding points of
two adjacent teeth on the threads.
2.3.2
Set Commissioning Parameters for Non-bus Control System
Before setting commissioning parameters for non-bus control system, ensure the
following:
•
Parameter
N50000 Control System Type
is set to
0
.
•
The used terminal board is
Lambda 5S
.
To set commissioning parameters for non-bus control system, do the following:
1.
To enter into
Param
functional area, press
.
2.
Press
1
→
F1
→
F8
, input the manufacturer password, find and set the
following operation parameters:
N11000 Encoder Feedback
Whether to enable encoder feedback.
N11001 Encoder Type
0: incremental encoder.
1: absolute encoder.
If an absolute encoder in non bus control system is used, it should be used
together with Lambda 5M terminal board. Otherwise, it cannot work normally.
3.
Press
2
→
F8
, input the manufacturer password, find and set the following axis
parameters:
N10010 Pulse Equivalent
It refers to the moving distance of screw or rotation degree of the rotary axis
per pulse sent by the system, the minimum available distance controlled by the
system as well.
A smaller value gets higher machining precision and surface quality; while a
larger value gets faster maximum feedrate.
It is suggested to set lower pulse equivalent under condition of meeting the
demand of feedrate.
N74020 Coarse Positioning Dir.
The moving distance in coarse positioning stage during returning to the
machine origin.
N74030 F in Coarse Positioning
The feedrate in coarse positioning stage during returning to the machine origin.