![WEIHONG NK300CX Manual Download Page 35](http://html.mh-extra.com/html/weihong/nk300cx/nk300cx_manual_952559035.webp)
上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD
35
/
53
2.
To turn off obtaining the IP address automatically, press
.
3.
Press
↑
or
↓
to select the target input box, and set the following addresses:
–
IP address: 192.168.1.188 (the first three digits should be the same with
that of PC, and the last digit should be different from that of PC)
–
Subnet mask: 255.255.255.0 (the same with PC)
–
Default gateway: 192.168.1.1 (the same with PC)
4.
To close
Network Setting
dialog box and save the settings, press
F7
.
The new networking information shows in
Network Connection Status
area in
Computer
interface.
3.1.2.2
Verify the Connection
This operation is used to verify whether the IP addresses are set successfully by
ping command after the IP addresses of
NK300CX
and PC are set well.
To verify the connection, do the following:
1.
To open the command window, press
Win
and
R
keys on the keyboard of PC,
and input
cmd
in
Run
dialog box.
2.
Input
ping
and IP address of
NK300CX
.
e.g. ping 172.16.60.172
。
3.
Press
Enter
, and check the result: