Replacement for body size 3
Î
Remove the o-ring with the
WEH
®
O-ring picker from the
housing.
Attention:
Do not damage the
O-ring when removing it.
Î
Remove the back-up ring with
the WEH
®
O-ring picker from
the housing.
Attention:
Do not damage the
back-up ring when removing
it.
Î
Lightly lubricate the o-ring
with the
WEH
®
Lubricant
part No. E99-40
.
Î
Insert the o-ring into the
recess behind the thread in
the housing.
Î
Lightly lubricate the back-up
ring with the
WEH
®
Lubricant
part No. E99-40
.
Î
Place the back-up ring into
the recess of the housing. The
ends of the slotted back-up
ring must interlock correctly.