WELD THE WORLD
Cod. 006.0001.0940
16/04/2018 V.2.25
WF-104
WF-108
37
ENGLISH
1
1
3
5
7
9
2
4
6
8
10
Wire speed (m/min)
High speed
Middle speed
Low speed
2
3
4
5
6
minute
Cycle 2puls
Freq 2puls
• CYCLE 2PULS
• Double pulsed duty cycle
○ The parameter adjusts the high feed rate time.
○ The value is expressed as a percentage over the pulse frequency period.
• ARC2 2PULS
• Arc2 voltage in double pulsed mode
○ The parameter corrects the synergic voltage value relative to the low wire feed rate of double
pulsed mode.
-
NOTE: A value >0 produces an increase in the length of the welding arc, while a value <0 pro-
duces a shorter arc.
• ARC2 2PULS
• Arc2 wire feed rate in double pulsed mode
○ The parameter corrects the synergic value of the wire feed rate relative to the low voltage value
of double pulsed mode.
-
NOTE: A value <0 produces an increase in the length of the welding arc, while a value >0 pro-
duces a shorter arc.