WECO 5K3-XP-EMEA
33
2.3.1
LOW VOLTAGE PARALLEL CONFIGURATION
The DIP switch must be set as follows to allow a single Battery Module to communicate with an inverter using CAN communications:
DIP CONFIGURATION UP TO FIFTEEN MODULES IN PARALLEL
From the 1
st
to the last module (or 15
th
) for a SINGLE CLUSTER in Low Voltage Configuration,
the DIP setting of each battery must be set as per the picture below:
For Single module Configuration*
When Multiple Module in Parallel, the last one must have the DIP 6 enabled**
*DIP Switch settings for multiple clusters are covered in a separate section of this manual.
** The DIP 6 Act as terminator and must be enabled when more than one module in parallel is used
2.3.2
LED Visual Indication Lights
There are three sources of visual indications on the Battery Module:
•
POWER SWITCH ON/OFF
•
RUN BUTTON GREEN LED
•
SIDE LED BAR Multi Color