25
9.
Connecting and configuring DIO ports
<ote> Wire Handling
Trimming Wire
When connecting a wire to a terminal block, follow the instructions below. Note the different types of
wire that can be used.
Standard Wire : Peel off the wiring, cover
8~10mm and solder it. Wire gage should be
AWG 22~26.
Solid Wire : Peel off the wiring cover 8~10mm
and solder it. Wire gage should be AWG 20~26
Inserting & removing wire
To insert & remove wirte in TERMINAL BLOCK,
use a screwdriver in the diagram to the right.
9.1.
Connecting and configuring sensor
9.1.1.
Specification
In order to run sensor input of eDVR MD800M normally, the following conditions are required.
Spec.
Input Ch.
8Ch Transister inputs
Input type
N.C (Normal Close)/ N.O. (Normal Open) type.
Supported sensor
Dry contact sensor
Connecting
Connecting the trimmed wire to terminal block
Performance
Available input pulse range
Min. 500ms
Output current
Typical DC 12mA
Summary of Contents for eDVR MD800M
Page 1: ...eDVR Installation Guide MD800M v 1 0...
Page 18: ...18 7 MD800M configuration 7 1 Basic Configuration 7 2 Advanced configuration...
Page 19: ...19 7 3 External storage Back up configuration 7 4 Internet Intranet configuration...
Page 32: ...32 9 3 2 1 Diagram of COM1 RS232 9 3 2 2 Diagram of COM2 RS485 9 3 2 3 Diagram of COM3 RS485...
Page 38: ...38 9 6 Connecting Video in output...
Page 47: ...47 APPENDIX APPE DIX APPE DIX...
Page 49: ...49...
Page 52: ...52...
Page 66: ...66 Mechanical Dimension W D H 420 0 x 294 0 x 98 0 Weight 5 5 kg with one HDD...