Pump and Fluid Systems
Chapter 5: Assembly/Disassembly
weatherford.com
77
MP-16 2-Piece 5000 psi January 2013
5.2.10
Removing the Pinion Shaft & Bearings
The following procedure outlines the removal of the pinion shaft bearings.
1
If necessary, unscrew and remove the key
from the pinion shaft keyway.
2
Disconnect the oil lube lines and drain and
then unbolt the pinion oil seal plate. Be sure
to support the pinion shaft to prevent it from
moving.
3
Slide the oil seal plate and spacer free of
the pinion shaft.