Granudos 45/100-CPR Touch XL + Touch + S5
Dosing unit
Index: 02
Date modified: 06/06/2019
OI No.: BA SW 003-02 Granudos 45-100 CPR Touch+Touch+S5-Dosiereinheit EN.docx Page 21 of 58
GRANUDOS 45/100-
S5
Buffertank GRANUDOS
-PB
(optional) for
CPR-Touch XL
und
Touch
Dimensions and weights:
Device dimensions
B 60cm, T 70cm, H 140cm
D 80cm, H 130cm
Device space requirement (base) B 130cm, T 80cm, H 200cm
W 90cm, D 90cm, H 180cm
Space requirement, incl.
operation and maintenance
B 140cm, T 170cm, H 210cm
W 90cm, D 170cm, H 210cm
Empty weight / operating weight Ca. 38kg / 83kg
200l = 10/210kg
300l = 15/315kg
Connection data
Electric connection data
230VAC/50Hz ± 10%, 350W,
I max. 3.15A, safety plug
Protection class
IP 54
Hydraulic connection data
Inlet DN25
Outlet DN20
Overflow dissolving unit DN20
Drain collecting basin DN25/32
Inlet DN20
Outlet DN15 (suction lance)
Required duct connection
At least DN25
Operating pressure
Required inlet pressure
Counter-pressure
max. 2.5barg
min. 0.2barg
0 - 1.5barg (depending on inlet pressure)
Pressureless
Water supply
Between circulation pump and filter, or
filter and heat exchanger, before chemical
dosing using the booster pump;
Flow pressure min. 0.2barg
Operating data:
max. dosing performance
GR 45-
GR 100
Chlorine: 1-2kg/h
(1)
Acid: max. 3l/h
(2)
Chlorine: 2-4kg/h
(1)
Acid: max. 3l/h
(2)
Water flow
approx. 800 – 1000l/h
Filling capacity of the dosing
device
max. 1200l/h
Filling volume
---
200l/300l
Booster pump
0.33kW, 230V, 1.95A
Medium temperature
Ambient temperature
Humidity engineering room
5°C to 35°C
5°C to 35°C
Max: 70%
5°C to 35°C
5°C to 35°C
Max: 70%
Concentration hypochloric acid GR 45: max. 0.2%
GR 100: max. 0.35%
max. 0.35%
Room ventilation (in and out)
The locally applicable provisions must be observed, e.g., DIN 19643 in Germany
Material
Upright column: Steel, galvanised and
painted
Other functioning parts: PVC or PE
Gaskets: EPDM, viton
Container: PE
Connections: PVC