Description

The ESP25 is a battery operated back-
up sump pump. It does not replace a
regular pump. It is designed to provide
protection in the event household
electrical power fails.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

Safety Guidelines

This manual contains information that is
very important to know and
understand. This information is provided
for SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols. 

Danger indicates an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.

Warning indicates a potentially
hazardous situation which, if not
avoided, could result in death or serious
injury.

Caution indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.

Operating Instruction and Parts Manual

ESP25 

352205-001 4/07

Notice indicates important information,
that if not followed, may cause damage
to equipment.

General Safety
Information

Do not use to pump
flammable or explosive
fluids such as gasoline,
fuel oil, kerosene, etc. Do
not use in a flammable
and/or explosive
atmosphere. Pump should
only be used to pump
clear water. Fatal injury
and/or property damage
could result.

If the basement has
water or moisture on the
floor, do not walk on wet
area until all power is
turned off. If the shutoff
box is in the basement,
call an electrician.
Remove pump and either
repair or replace. Failure
to follow this warning
could result in fatal
electrical shock.

All wiring must be performed by a
qualified electrician.

Do not expose battery to

sparks or flames as an

explosion or fire could result.

Battery acid is corrosive.

Avoid spilling on skin or

clothing. Eye protection must

be worn when handling the battery.

A check valve must be used on the
primary sump pump discharge.

A ground fault circuit interrupter is
required. 

This pump must only be used to pump
clear water. This pump is not designed
to handle effluent, salt water, brine,
laundry discharge or any other
application which may contain caustic
chemicals and/or foreign materials.
Pump damage may occur if used in
these applications and will void
warranty.

Battery Information

The system is designed to operate most
efficiently with sealed lead acid (SLA)
batteries. Deep cycle marine batteries
or automotive style batteries can also
be used. 

Sealed lead acid batteries cost slightly
more, but they can last longer. Among
the manufacturers of sealed lead acid
batteries are Hawker, Panasonic,
PowerSonic, Yuasa and Eagle Picher.

The oversize battery case (included) will
accommodate a 12-volt SLA battery or
a 12-volt deep cycle marine battery (up
to a 27-frame size).

12-Volt 
Backup 
Sump Pump

© 2007 Wayne Water Systems

For parts, product & service information

visit 

www.waynepumps.com

Summary of Contents for 352205-001

Page 1: ...t General Safety Information Do not use to pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in a flammable and or explosive atmosphere Pump should only be used to p...

Page 2: ...park or short circuit the system or battery causing an explosion Installation Installation of this unit may take several hours Before disabling your main pump have ready an appropriate means of evacua...

Page 3: ...11 2 NPT discharge If a 11 4 discharge pipe is desired an adapter not included will be necessary Smaller diameter piping will reduce pump flow rate and performance 3 A check valve will be required in...

Page 4: ...ectrical shock could occur Risk of electrical shock Use a GFCI receptacle to reduce the risk of fatal electrical shock Cutting the cord or plug will void the warranty and make the pump inoperable 1 Af...

Page 5: ...lly 5 If pump operates normally plug charger into wall outlet turn on main pump If pump fails to operate normally see Troubleshooting guide and correct problem Repeat step 5 BATTERIES Dangerous hydrog...

Page 6: ...the 7 screws on the bottom of the pump to release the housing around the impeller Remove the obstruction Reassemble pump and reconnect 1 Check to make sure check valves installed between primary pump...

Page 7: ...lease provide following information Model number Serial number if any Part descriptions and number as shown in parts list 1 3 5 4 6 www waynepumps com 1 Bracket 46049 001 1 2 Charger 30221 001 1 3 Con...

Page 8: ...TSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitat...

Page 9: ...la tion de fils doit tre effectu e par un lectricien qualifi Ne pas exposer la pile des tincelles ou des flammes Une explosion ou un feu peut y r sulter L acide de pile est corrosive Ne pas le renvers...

Page 10: ...et du savon Ne jamais fumer ou laisser une tincelle ou une flamme pr s de la batterie 10 Fr Instructions d Utilisation et Manuel de Pi ces viter de laisser tomber des outils de m tal sur les bornes d...

Page 11: ...u ne g le pas dans le tuyau En installant le tuyau de d charge distinct percer dans le mur ext rieur avec l quipement de per age appropri Sceller le trou pour viter que l eau n y p n tre M thode 2 S i...

Page 12: ...exions indiqu es sur la bo te 4 Faire l essai de la pompe en remplissant le puissard d eau pendant que la pompe principale est d branch e Si la pompe fonctionne correctement brancher le chargeur dans...

Page 13: ...cher le chargeur et la pompe principale c a Si l alimentation c a est coup e et la pompe fonctionne la lampe indicatrice indiquera l tat de la batterie 4 Un son de p piement de la bo te de contr le ac...

Page 14: ...D brancher le chargeur de la prise du mur et l enlever Si le fusible est saut le remplacer avec un fusible d automobile de 20 A 1 V rifier la batterie et la remplacer si faible ou d fectueuse 2 D bra...

Page 15: ...pla t fournir l information suivante Num ro du Mod le Num ro de S rie si pr sent Description et num ro de la pi ce 1 Sangle 46049 001 1 2 Chargeur 30221 001 1 3 Bo te de contr le 30222 002 1 4 Vis bo...

Page 16: ...e pour les garanties implicites ni l exclusion ni la limite des dommages fortuits ou indirects Les limites pr c dentes peuvent donc ne pas s appliquer Cette garantie limit e donne l acheteur des droi...

Page 17: ...a reconocer esta informaci n observe los siguientes s mbolos sto le indica una situaci n de riesgo inminente la cual si no se evita puede ocasionar la muerte o graves lesiones sto le indica una situa...

Page 18: ...ojos cuando est trabajando cerca de bater as de plomo cido 1 Desconecte la corriente que va a la bomba principal 2 La bomba debe instalarse utilizando una tuber a r gida de PVC de 3 2 cm 11 4 3 8 cm 1...

Page 19: ...es de la bomba 2 Esta bomba tiene una descarga de 11 2 pulg NPT 3 8 cm Si se desea utilizar tuber a de descarga de 11 4 pulg NPT 3 2 cm ser necesario instalar un adaptador no incluido Las tuber as de...

Page 20: ...itivo de la bater a y el cable negro al borne negativo Ponga la tapa a la caja Si los cables se conectan al rev s puede da arse la caja de control o la bater a y la garant a ser invalidada 2 Coloque l...

Page 21: ...comprobar el nivel electrol tico y mantenerlo de conformidad con los lineamientos impartidos por el fabricante La carga para cada pila se debe verificar con un hidr metro Una gravedad espec fica de 1...

Page 22: ...ared y retire el fusible Si est quemado c mbielo por un fusible tipo auto motor de 20 amperios 1 Revise la bater a y reempl cela si est baja o defectuosa 2 Desconecte la bomba retire la rejilla y revi...

Page 23: ...lio S rvase proporcionar la siguiente informaci n N mero del modelo N mero de serie de haberlo Descripciones y n mero de piezas tal como aparecen en la lista de piezas 1 M nsula 46049 001 1 2 Cargador...

Page 24: ...S POR DA OS INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan l mites en la duraci n de las garant as implicitas o no permiten que se excluyan ni se establezcan...

Reviews: