![background image](http://html1.mh-extra.com/html/watts/tekmar-563/tekmar-563_installation-manual_3859943007.webp)
7 of 36
WiFi Thermostat 563
Rh1
W1
Acc1
Acc1
Rh2
W2
Rc
Y1
G
Y2
C
Y1
Y2
HUM
HUM
C
R
AWAY
S1
S3
S2
RH
3V3
SEN
COM
Acc2
O/B
Acc2
O/B
C
R
AWAY
W
C
R
DHUM
W2
Y2
Y1
G
+V
Com
%R
h
Sen
C1
C1
F1
F1
B1
T1
S1
S1
S2
S2
V1
V2
ZVC1
ZVC1
BP
PS
H1
H1
Electrical
-----------------------------------------------------------
-----------------------------------------------------------
C
R
AWAY
S1
S2
S3
RH
3V3
J1 J2 J3
RELAY
POWER
JUMPER
ON
OFF
SEN
COM
Rh1
Rh2
W2
W1
Rc
J1
R
Y1
Y2
G
Acc1
Acc1
Acc2
O/B
Acc2
O/B
WiFi Thermosta
t
563
R
J2
J3
R
Mechanical
----------------------------------------------------------
----------------------------------------------------------
The WiFi Thermostat 563 operates a first stage radiant floor and a second stage fan coil
for heating, and two-stage air conditioner for cooling and dehumidification, and a humidifier.
Legend
B1 = Boiler
BP = Boiler Pump
C1 = Air Conditioner
H1 = Humidifier
F1 = Fan Coil
PS = System Pump
S1 = Optional Slab Sensor 079
S2 = Optional Humidity &
Temperature Sensor 086
T1 = WiFi Thermostat 563
V1 = Radiant Zone Valve
V2 = Fan Coil Zone Valve
ZVC1 = Zone Valve Control 304V or 306V
Thermostat
jumpers:
J1 = On
J2 = Off
J3 = Off
and install field jumper
wire from Rh2 to Rc
and Rh2 to Acc2
Application 563-2