The thermostat can operate 3 types of humidifiers:
Stand Alone 

• The humidifier is not connected to the HVAC system.

   

 

• The thermostat Mode can be set to Heat, Cool, Auto or Off.

Steam   

• The  steam humidifier is ducted to the HVAC system.

   

 

• The thermostat Mode can be set to Heat, Cool, Auto or Off.

   

 

• Requires the system fan to turn on when operating.

Evaporative 

• A drum style humidifier which requires the heating system to  

   

 

operate  to evaporate the water. 

   

 

• This system requires the system fan to operate.

   

 

• The thermostat Mode must be set to Heat or Auto.

Humidifier Window Protection

During cold weather, condensation will form on windows when the relative humidity 

(RH) is too high. The optional window protection feature automatically calculates the 

indoor dew point based upon the outdoor temperature and the quality of the windows 

installed. The humidifier is then operated to the highest possible RH that is below the 

Humidify To setting.

Dehumidifier Operation

The thermostat controls the relative humidity (RH) by operating either the Accessory 

1 or Accessory 2 relay. This is an installer configurable setting. When the RH is above 

the Dehumidify To setting by 3%, the Accessory 1 or 2 relay is closed to operate the 

dehumidifier. The dehumidifier is shut off when the RH reaches the Dehumidify To setting.
The thermostat can operate 2 types of dehumidifiers:
Stand Alone 

• The dehumidifier is not connected to the HVAC system.

   

 

• The thermostat Mode can be set to Heat, Cool, Auto or Off.

DX Coil   

• The HVAC cooling system is used for dehumidification.

   

 

• The Accessory 1 or Accessory 2 relay activates the DHUM  

   

 

operation on the air handling unit to operate the system fan at low  

   

 

speed.

   

 

• The cooling compressor Y1 and Y2 relays are operated. The  

   

 

chilled DX coil condenses moisture from the air.

   

 

• The cooling system can over cool the room temperature by 2°F  

   

 

(1°C) during dehumidification.

Ventilation with fresh outdoor air is important for maintaining indoor air quality. The 

thermostat can operate a heat recovery ventilator (HRV) or energy recovery ventilator 

(ERV) on a timer by closing the Accessory 1 relay to operate the ventilator fan at low 

speed.

The thermostat supports water-to-air heat pump systems that absorb or reject heat to a 

hydronic building loop. Whenever the heat pump compressor Y1 or Y2 relay is turned 

on, the Accessory 1 relay closes to open a hydronic zone valve. This allows variable 

speed pumps on the hydronic loop to operate at lower speeds when the heat pump is 

off, thereby saving electrical energy.

HRV / ERV Ventilator Operation

 ---------------------------------------

 ---------------------------------------

Heat Pump Loop Valve Operation

 -------------------------------------

 -------------------------------------

Summary of Contents for Tekmar 563

Page 1: ...ional systems 2 stage heating 2 stage cooling fan and 2 accessories Heat pump systems 4 stage heating 2 stage cooling fan reversing valve and 1 accessory Supports dual fuel systems Accessory options H...

Page 2: ...e Humidity Operation 12 HRV ERV Ventilator Operation 13 Heat Pump Loop Valve Operation 13 User Interface 14 User Settings 15 Away 15 Schedule 15 Display 16 Time 17 Fan 17 WiFi 18 WiFi and Connectivity...

Page 3: ...moderate injury This symbol identifies practices actions or failure to act which could result in property damage or damage to the equipment Read Manual and all product labels BEFORE using the equipme...

Page 4: ...environment No exposure to extreme temperatures beyond 32 122 F 0 50 C No draft direct sun or other cause for inaccurate temperature readings Away from equipment appliances or other sources of electr...

Page 5: ...mostat Base C R AWAY S1 S2 S3 RH 3V3 J1 J2 J3 RELAY POWER JUMPER ON OFF SEN COM Rh1 Rh2 W2 W1 Rc J1 R Y1 Y2 G Acc1 Acc1 Acc2 O B Acc2 O B WiFi Thermostat 563 R J2 J3 R C R AWAY S1 S2 S3 RH 3V3 J1 J2 J...

Page 6: ...563 operates a one or two stage furnace for heating a one or two stage air conditioner for cooling a humidifier and a heat recovery ventilator C R AWAY S1 S2 S3 RH 3V3 J1 J2 J3 RELAY POWER JUMPER ON...

Page 7: ...R J2 J3 R Mechanical The WiFi Thermostat 563 operates a first stage radiant floor and a second stage fan coil for heating and two stage air conditioner for cooling and dehumidification and a humidifie...

Page 8: ...l Humidity Temperature Sensor 086 T1 WiFi Thermostat 563 V1 Radiant Zone Valve V2 Fan Coil Zone Valve ZVC1 Zone Valve Control 304V or 306V WiFi Thermostat 563 Rh1 W1 Acc1 Acc1 Rh2 W2 Rc Y1 G Y2 HUM HU...

Page 9: ...0 F 21 C Legend B1 Boiler C1 Cooling Tower BP Boiler Pump CP Cooling Tower Pump HP1 Heat Pump PS System Pump T1 WiFi Thermostat 563 V1 Heat Pump Loop Valve WiFi Thermostat 563 Rh1 W1 Acc1 Acc1 Rh2 W2...

Page 10: ...W1 W1 W1 W1 Second stage heating W2 W2 First stage cooling Y1 Y1 Y1 Y1 Second stage cooling Y2 Y2 Fan G Accessory 1 Choice of Humidifier Dehumidifier HRV ERV Accessory 2 Choice of Humidifier Dehumidi...

Page 11: ...the stage turns on and shut off when they reach 1 5 1 0 and 0 5 F 0 75 0 5 and 0 25 C of the Heat To setting respectively Radiant Floor Heating Radiant floor heating is operated differently than othe...

Page 12: ...omical to shut off the heat pump relays Y1 and Y2 and operate the backup heating equipment relays W1 and W2 Dual Fuel Dual fuel systems include a heat pump together with a backup heat source such as a...

Page 13: ...lay is closed to operate the dehumidifier The dehumidifier is shut off when the RH reaches the Dehumidify To setting The thermostat can operate 2 types of dehumidifiers Stand Alone The dehumidifier is...

Page 14: ...ature to the current schedule event Go to settings Swipe to view Weather Outdoor temperature Floor temperature Heat To setting Cool To setting Relative Humidity Go to schedule After 60 seconds of inac...

Page 15: ...inked to that location through the app Save Info Home Away At Home Away Heating temperature Go to the next group of program days Current group of program days Early Start anticipates the time required...

Page 16: ...TNESS ACTIVE Select the brightness when touching the screen 30 to 100 100 BRIGHTNESS INACTIVE Select the brightness when not in use Off 30 to 100 50 BACKGROUND Select the background color Light Blue N...

Page 17: ...atically The time and date can be manually set by highlighting a field and then using the or buttons Choose from the time options listed below Incorrectly setting the time and date manually may preven...

Page 18: ...of Use as amended from time to time and available at Watts com terms of use If you do not accept these terms this product can still be used without WiFi features Tutorial DISAGREE AGREE Before first u...

Page 19: ...be on Then power the thermostat on Check Router Firewall ConsulttheroutermanualorInternetService Provider ISP for assistance with router setup with these configurations The router must provide a 2 4...

Page 20: ...r access levels User access level restricts access in the Setup Menu User Installer Installer STATUS The current status of warm weather shut down cold weather shut down and each of the relays Early St...

Page 21: ...over heating Applies when there is a floor sensor Off 40 to 95 F Off 4 5 to 35 0 C Off Screen Page 2 HEAT TO AWAY Select the heating temperature when away Off 40 to 95 F Off 4 5 to 35 0 C 62 F 16 5 C...

Page 22: ...rature sensor is on or off Only available when Sensor 1 2 or 3 is set to read a room or floor sensor Off On On INTERNAL HUMIDITY SENSOR Select if the internal humidity sensor is on or off Only availab...

Page 23: ...ING Sends an email notification if the humidity rises above this setting Off 5 to 95 Off AUXILIARY HEAT RUN TIME WARNING Sends an email notification if the auxiliary heat W1 or W2 runs continuously fo...

Page 24: ...e first stage heating is turned on This setting is available when there are at least 2 heating stages 0 to 180 minutes 1 minute HEAT 3 DIFFERENTIAL Select when the third stage heating turns on Turn on...

Page 25: ...r must run before shutting off This helps prevent compressor failure 0 30 to 10 00 minutes 2 00 minutes Y MIN OFF TIME Select the minimum time the cooling compressor must be off before turning back on...

Page 26: ...he outdoor temperature is available through WiFi or auxiliary sensor Off or On Off WINDOW QUALITY The window quality determines the amount that the relative humidity setting is lowed during cold outdo...

Page 27: ...r 2 operates a humidifier Set the highest relative humidity level Range is 20 to 90 Default is 60 Available when Accessory 1 or 2 operates a dehumidifier When a programmable schedule is used there is...

Page 28: ...t Apple or long hold Android to edit the Location name Step 2 On the thermostat go to WiFi menu and press Register Device Step 5 Enter the 8 digit code from the thermostat into the mobile app Then ent...

Page 29: ...temperature setting Limits Mode Current temperature Press Bars for settings Swipe left or long hold to edit or remove location Swipe left or long hold to edit or remove device Calendar alt Edit sched...

Page 30: ...loor sensor or if a floor maximum temperature has been set Check the auxiliary sensor wire for short circuits according to the sensor installa tion manual It may be necessary to replace the auxiliary...

Page 31: ...ITY WARNING The relative humidity is above the High Humidity Warning setting in the Alerts menu The warning will automatically clear once the relative humidity falls below the setting AUXILIARY HEAT R...

Page 32: ...32 of 36 Page intentionally left blank...

Page 33: ...33 of 36 Page intentionally left blank...

Page 34: ...34 of 36 Page intentionally left blank...

Page 35: ...FCC Part 15 Ambient conditions Indoor use only 32 to 122 F 0 to 50 C RH 90 non condensing Environmental Do not use in presence of ammonia animal barns Power supply 15 to 30 V ac dc 2 VA Class 2 Relays...

Page 36: ...Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation Pur chaser shall indemnify and...

Reviews: