Error Codes (Cont.)
Code
Problem
Resolution
125
Resistor ID fusion cannot be com-
pleted because the value was not
decoded into a valid fusion time.
Verify that the fitting and the processor both sup-
port the Resistor ID method. If so, the problem is
with the fitting, the output cable or the processor
calibration. If the problem persists with multiple
fittings, the processor will have to be returned
for service.
130
The fitting was disconnected before
the specified cooling time.
Do not disconnect the fitting before the manufac-
turer's recommended cooling time has expired.
131
An undefined error was received be-
fore the fusion time was completed.
Processor must be returned for service.
132
Processor supports voltage control
only and fusion specified is not
voltage control.
Not all processors support current or energy
control. Attach a fitting that requires voltage
control or contact an authorized representative
(See page 13) to see if an update is available for
your processor.
138
The fitting was disconnected before
the specified countdown time
elapsed.
Do not disconnect the fitting before the manu-
facturer's recommended countdown time has
expired.
140
The fusion was shut off to protect
the processor from damage due to
extremely high fusion current.
This is typically caused when a direct short is
made across the Output Lead Ends. It there
are no obvious problems with the fitting or the
output cable, them the processor will need to be
returned for service.
141
The ambient temperature is too low
to fuse fittings of this type.
Same as Error 101.
142
The processor believes that the
same fitting was fused twice.
Do not fuse a fitting more than two times unless
directed so by the fitting manufacturer.
143
The fitting was disconnected before
the specified heat soak time was
observed.
Do not disconnect the fitting before the man-
ufacturer's recommended heat soak time has
expired.
144
The output is cycling and cannot be
controlled to the requested level.
This is more than likely caused by a fluctuating
power supply. Eliminate all extension cords and
ensure that the processor is the only device
operating on the circuit.
145
There is an error communicating
with the USB Flash Drive.
Be sure the drive is formatted as FAT or FAT32
with a cluster size of 512 bytes.