Error Codes (Cont.)
Code
Problem
Resolution
109
Reference voltage out of tolerance.
Processor must be returned for calibration. You
cannot fuse if the error is detected.
110
STOP pressed during previous
fusion.
Do not press the STOP button during the fusion
unless in an emergency situation.
111
Fusion complete with no other
errors.
There were no problems with this fusion.
112
Fitting disconnected
Current drops close to 0 during the fusion. If
the problem persists there is more than likely an
output cable problem and the processor should
be returned for service.
113
The calibration date has expired.
Send the processor in for calibration.
114
There is no valid calibration date set.
Send the processor in for calibration.
115
The processor is not capable of
outputting the current required to
fuse this fitting
As long as the fitting's fusion requirements
are within the specified output range of the
processor, this could be an output cable error or
a calibration error. Try cleaning the Output Lead
Ends. If the problem persists, the processor will
need to e returned for service.
116
The processor is not capable of
outputting the voltage required to
fuse this fitting.
117
Input voltage is out of range and the
fusion cannot start.
Verify that the input voltage and frequency
displayed on the CONNECT LEADS screen are
reasonable and within the range specified in the
Specification Table (See page 6). If the parame-
ters displayed differ significantly from the actual
input, then there is a processor problem and it
must be returned for service.
118
Frequency is out of range and the
fusion cannot start.
119
Internal processor temperature is
out of range.
Allow the processor to cool before fusing again.
This error can be seen if multiple large fittings are
fused one after the other.
120
A time of 0 seconds for the fusion
was entered or calculated.
This is more than likely a temperature measure-
ment problem. Verify the temperature displayed
in the CONNECT LEADS screen is reasonable
and within the range specified in the Specifi-
cation Table (See page 6). If the temperature
displayed differs significantly from the actual
temperature the there is a processor problem
and it must be returned for service.
121
Invalid Operator ID card scanned.
Verify the system date is correct and, if so, con-
tact the agency that issued the Operator ID card.
122
Not an Operator ID card.
Contact the agency that issued the Operator ID
card.
123
The Operator ID card scanned
does not contain privileges for the
functions this machine is capable of
performing.
124
Current offset is out of spec.
Processor must be returned for calibration. You
cannot fuse if this error is detected.