Warnings & Error Codes

Warning Codes

A warning code will be displayed when a situation exists that (in the manufacturer's opinion) may 

adversely affect the performance of the processor over time. Warning codes are designed for 

informational purposes only and have no effect on the outcome of a fusion. A warning code may 

be displayed either before or after a fusion and will require operator acknowledgment before normal 

operation can resume.

It is strongly recommended that operators familiarize themselves with all warning codes 

and their causes and adhere to the recommendations below when they are received.

Error Codes

Code

Description

Cause

Recommendation

53

Low

Temperature

Advisory

Occurs when the ambient 

temperature read by the 

processor is less than 50°F.

Consult Orion Engineering Department 

at 

910-865-7530

 for pre-heat instruc-

tions before proceeding with fusions in 

temperatures at less than 50°F.

Code

Problem

Resolution

100

The barcode was scanned success-

fully, however the processor cannot 

decode the information into valid 

fusion parameters.

This is not a barcode wand error or scanning 

problem. Verify that the barcode is an ISO stan-

dard 24 digit fitting barcode.

101

Ambient temperature is out of range. Verify the temperature displayed in the CON-

NECT LEADS screen is reasonable and within 

the range specified in the Specification Table 

(See page 6). If the temperature displayed differs 

significantly from the actual temperature, then 

there is a processor problem and it must be 

returned for service.

102

Measured resistance does not 

match resistance identified in the 

barcode.

Check Output Lead Ends for excessive wear 

and/or damage. If the Output Lead Ends are in 

good condition, reattach the processor to the 

fitting and try again. If the problem persists, there 

is more than likely a calibration or output cable 

malfunction.

103

Shorted coil in fitting.

Check for a short stab or a shorted coil.

105

Can't maintain output voltage.

Verify the Output Lead Ends are clean, the 

power supply is sized correctly for the fitting you 

are fusing, and the power supply is operating 

correctly.

108

The power supply was shut off 

during the previous fusion.

This could be anything from an improperly sized 

generator to someone switching the processor 

off during a fusion.

Summary of Contents for ORION Rionfuser

Page 1: ...ricity electrocution and shock hazards Local building or plumbing codes may require modifications to the information provided You are required to consult the local building and plumbing codes prior to...

Page 2: ...3 Setting the Language 24 Smart Scanner 24 Advanced User 24 25 Short Stab Detect 24 Operator ID 24 Profiles 24 Appendix 25 Connecting Multiple Fittings 25 Entering Data with the Keypad 25 Downloading...

Page 3: ...enclosures be opened All warranties are void if the factory seal has been broken Before any fusion is performed it is the responsibility of the operator to always verify that all the information disp...

Page 4: ...n with its advice The integrity of the piping system is the ultimate responsibility of the installer This publication is not to be taken as a license to operate under or rec ommendation to infringe an...

Page 5: ...rial Port 9600 8 n 1 N A N A Type A USB Port N A USB A type connector for attaching a USB flash drive to download fusion data N A Type B USB Port N A USB B type connector for attaching the AutoCal fie...

Page 6: ...button may mean STOP RESET or CANCEL depending upon the context of the operation being performed at the time 4 The UP button and DOWN button are used to scroll through the various menus These but tons...

Page 7: ...7 Faceplate Controls Faceplate Controls START button Replaceable Display Shield UP button DOWN button STOP button 4X20 LCD Display Temperature Sensor RF 3000LE Bluetooth RF 3000LE Bluetooth...

Page 8: ...8 START button Replaceable DisplayShield UP button DOWN button STOP button 4X20 LCD Display Temperature Sensor USB Type A Port USB Type B Port RF 3000LE USB RF 3000LE USB Faceplate Controls...

Page 9: ...on UP button DOWN button STOP button 4X20 LCD Display Temperature Sensor Serial Port Emergency STOP Switch GFCI Rionfuser LT Input Cable Emergency STOP Switch Fuse Output Cable Buzzer RF 3000LE Side P...

Page 10: ...10 Cables Output Cable Input Cable RF 3000LE GFCI Input Cable 4 0mm Lead Ends Field Replaceable Shown...

Page 11: ...l help ensure proper operation 1 Keep the area around the Temperature Sensor clean and free of obstructions by wiping with a soft dry towel This is a critical area to keep clean as dirt will affect th...

Page 12: ...cessor will display the message Error 113 Calibra tion Required informing the operator that the calibration date has passed This will not prevent the processor from performing fusions however the proc...

Page 13: ...TOP switch to turn the processor ON Test the GFCI by pressing the Test button followed by the RESET button After the processor has turned ON startup screens similar to the following will be displayed...

Page 14: ...line on the CONNECT LEADS screen indicates the generator status The voltage and the frequency are displayed It is important that the voltage measurement is within the allowable range and the frequenc...

Page 15: ...llows the operator to automatically select between one of several fusion settings pre programmed for a variety of PVDF fitting sizes Manual Fusion allows the operator to manually configure the fusion...

Page 16: ...is being performed in an environment where the ambient temperature is below 50 F please consult Orion Engineering Department at 910 865 7530 for pre heat instructions before proceeding All other fusi...

Page 17: ...on is being performed in an environment where the ambient temperature is below 50 F please consult Orion Engineering Department at 910 865 7530 for pre heat instructions before proceeding All other fu...

Page 18: ...s specified by the fitting manufacturer When beginning a Manual Fusion the following screen will be displayed Enter the fusion current by using the UP button and DOWN button to increment and decrement...

Page 19: ...e is displayed press the START button ENTER FUSION TIME 1 min 30 sec Failure to verify that the fusion information is correct before start ing a fusion could result in signifi cant damage to personal...

Page 20: ...verify the information on this screen is correct before pressing START The processor will BEEP once per second and the text PRESS START on the bottom line of the display will flash on and off Once yo...

Page 21: ...n this case 118 volts The current generator frequency This number should remain relatively constant throughout the fusion When the fusion is complete if no errors were encountered during the fusion pr...

Page 22: ...lowing screen will be displayed With the keypad see page 25 enter the correct date using the MM DD YYYY format and the correct time using the 24 hour military format Press START button to save the inf...

Page 23: ...orrect passcode has been entered Use the UP DOWN buttons to highlight the desired option Press the START button to access the desired option Press the STOP button to return to normal operation Short S...

Page 24: ...he cursor up to the previous character and change it If the STOP button is pressed while on the first character the processor will back up to the previous screen Repeat this procedure until all data i...

Page 25: ...g was fused Mea Res The resistance of the fitting specified in the barcode Tolerance The specified resistance tolerance Mea Res Pre The actual measured resistance of the fitting before the fusion Mea...

Page 26: ...e fusion data will be written to the drive 4 A progress screen similar to the following will be displayed as the download proceeds 5 After the download is complete the processor will return to the CON...

Page 27: ...pp perform the following steps 1 Turn ON the processor and allow it to proceed through the INTERNAL SELF TEST until it reaches the CONNECT LEADS screen 2 Open the EF Utilities app on your smart phone...

Page 28: ...ield environment The most probable cause of fuse failure is a defective or inappropriately sized generator If you have a fuse problem check your generator first Tools Required 1 8 Flat Blade Screwdriv...

Page 29: ...other accessories wear tear etc Before starting a fusion it is important to make sure the generator has enough fuel to complete the electrofusion cycle the auto throttle is disengaged in anticipation...

Page 30: ...l look similar to this The processor will countdown the number of days until calibration is due The text mm dd yyyy shows the month day and year that the calibration is due To avoid being locked out o...

Page 31: ...bient Temperature Warning This section applies to the RF 3000LE Electrofusion Processor only Fusions performed in ambient temperatures less than 50 F may require additional preparation and instruction...

Page 32: ...valid fusion parameters This is not a barcode wand error or scanning problem Verify that the barcode is an ISO stan dard 24 digit fitting barcode 101 Ambient temperature is out of range Verify the te...

Page 33: ...tart Verify that the input voltage and frequency displayed on the CONNECT LEADS screen are reasonable and within the range specified in the Specification Table See page 6 If the parame ters displayed...

Page 34: ...countdown time elapsed Do not disconnect the fitting before the manu facturer s recommended countdown time has expired 140 The fusion was shut off to protect the processor from damage due to extremely...

Page 35: ...use misuse misapplication improper installation or improper maintenance or alteration of the product Some States do not allow limitations on how long an implied warranty lasts and some States do not a...

Reviews: