A p p l i c a t i o n 3
Wa t l o w M
I N I
C
H E F
2 0 0 0
■
2 5
Configuration Mode Quick Reference
These are the functions, parameters and values included in the Configuration Mode for
this application. You must select Application 3 to access them. For directions, see the
Hardware & Software Setup Guide. The Appendix of that guide includes an explanation
of all parameters and values.
F
unction
Parameter
Value
Your Settings
[Etype]
Equipment-Type
[appl`]
Application Number
1 - 28
3
[a_Loc]
Application Number
Security Lock
No, Yes
[Sound]
Audible Alarm Sound
0 - 5
[FAn``]
Fan Speed
1 spd, 2 spd
[delay]
Fan Delay Time
0 - 120
[SEtUP]
Setup
[`Ç_Ï`]
Temperature Display Format
°C or °F
[time]
Time Display Format
MMM:SS, HH:MM, H:MM:SS
[Chirp]
Key Chirp
On, Off
[loc``]
Menu Security Lock
Yes, No
[tc```]
Thermocouple Type
J, K (shown as
[````H]
), E
[rtd``]
RTD Curve
DIN, JIS
[tconp]
WatCurve
TM
Temperature
On, Off
Compensation
[Ofst1]
Temp Offset, Channel 1
-99 to 99°F, (-55 to 55°C)
[tr`lo]
Temperature Range Low
0ºF (-18º C) for RTD inputs,
32ºF (0ºC) for tc inputs to
[tr`Hi]
[tr`Hi]
Temperature Range High
[tr`lo]
to 1200°F (649°C)
[ready]
Preheat Ready Feature
Yes, No
[rband]
Ready Band
1 to 1200°F (1 to 649°C)
[Cloc`]
Real Time Clock Display
Yes, No
[plOSS]
Power Loss Menu Resume
Yes, No
[al``1]
Alarm 1
None, Dev, Proc, Both
[aL`P1]
Absolute Process Alarm 1
100 to 1200°F (38 to 649°C)
[aLdL1]
Low Deviation Alarm 1
-999 to 0°F (-555 to 0°C)
[aLdH1]
High Deviation Alarm 1
0 to 999° F (0 to 555°C)
[tHErl]
Thermal
[tyPE`]
Temperature Control Type
PID, On-Off
[HYSt1]
Hysteresis 1
1 to 999°F (1 to 555°C)
[Pid`U]
PID Units
SI, US
[tune1]
Auto-tuning 1
on, OFF
[ProP1]
Proportional Band 1
1 to 999°F (1 to 555°C)
[rSEt1]
Reset (integral) Gain 1
0.00 to 9.99 repeats/minute
[int`1]
Integral Gain 1
0.00 to 99.99 minutes/repeat
[rAtE1]
Rate (derivative) Gain 1
0.00 to 9.99 minutes
[dEr`1]
Derivative Gain 1
0.00 to 9.99 minutes
[CYcL1]
PID Cycle Time 1
1 to 60 seconds
[`diag]
WatHelp
Used for equipment troubleshooting and testing. Not used when programming. See the Hardware
Diagnostics
& Software Setup Guide.