1 4
■
Wa t l o w M
I N I
C
H E F
2 0 0 0
A p p l i c a t i o n 2
Program Mode Quick Reference
These are the functions, parameters and values included in the Program Mode for this
application. You must select Application 2 to access them. For menu programming direc-
tions, see the Hardware & Software Setup Guide. The Appendix of that guide includes a
detailed explanation of all parameters and values.
F
unction
Parameter
Value
Your Settings
[M``]
Menu Numbers 1 - 17
[Stpt1]
Set point 1
Temp range low
Temperature of set point 1.
to temp range high
[TiNe1]
Time 1
Setting both Time 1
Run time of set point 1.
and Time 2 at 0 invalidates
selected menu.
Format varies based
on configuration.
[fan`1]
Fan 1 Speed
Single Speed: On, Off
Speed of fan 1 during time 1
Two Speed: Off, Low, Hghi
[Stpt2]
Set point 2
Temp range low
Temperature of set point 2.
to temp range high
[TiNe2]
Time 2
Setting both Time 1 and
Run time of set point 2.
Time 2 to 0 invalidates
selected menu.
Format varies based
on configuration.
[fan`2]
Fan 2
Single Speed: On, Off
Speed of fan during time 2
Two Speed: Off, Low, High
[Probe]
Probe
On, Off
Activates probe function.
[ptenp]
Probe Temperature
Temp range low
Temperature at which probe
to temp range high
will switch controller to
hold condition.
[Hstpt]
Hold Set point
Temp range low
Temperature at which the
to temp range high.
oven will operate during
hold sequence
[Htine]
Hold Time
0 = infinite. A setting >0
Run time of hold sequence.
= hold time.
Format varies based
on configuration.
[H`fan]
Hold Fan
Single Speed: On, Off
Speed of fan during hold time.
Two speed: Off, Low, High
Auto-tuning Note:
Before auto-tuning Application 2, Set Point 1 of Menu 1 must first be set to a value that
is typical of your application. (See the Hardware & Software Setup Guide for informa-
tion on programming menus.) Then set
[tHErL]
/
[tunE1]
to
[```on]
. After you
accept
[```on]
, by pressing “Enter,” the controller will display
[`tunE]
while auto-
tuning is taking place.
The controller will cancel the auto-tuning process if it cannot be completed in 80 min-
utes. You can cancel the auto-tuning process at any time by pressing either key C or key
D and accepting
[``Off]
, by pressing “Enter,” when it appears.