SECTION  1A:  EXTERIOR CONTROL OVERVIEW

The  exterior steam generator control features an adjustable time and temperature control with digital display. The actual room temperature and time remaining are 

alternately displayed every 5 seconds.  The exterior control is to be mounted outside the steam room.  

The temperature can be adjusted in one degree intervals from 100° to 125 °F (38° to 52°C) 

Fahrenheit with an initial default of 120°F (49°C).  Once the set temperature is reached the ''soft steam'' feature automatically engages, cutting steam production 

back to a single element to provide softer billowing steam during more of the steam bath.  If the steam room temperature drops more than 5°F (3°C) both elements 

will automatically engage.

 

SECTION  1B:  INTERIOR CONTROL OVERVIEW

The interior steam generator control  features the  same control  attributes as the exterior.  

Programming adjustments/changes can be performed in the same manner described in Section 1A above. The interior control also features a built-in sensor and 

must be mounted inside the steam enclosure. 

The built-in sensor supplies information on room temperature to the generator thus insuring a comfortable steam experience. Once the temperature is reached the 

"soft steam" feature automatically engages cutting steam production back to a single element to provide softer billowing steam during more of the steam bath. If the 

steam room temperature drops more than 5°F (3°C) both elements will automatically engage.

 

SECTION  2:  OPERATION OF YOUR EXTERIOR AND INTERIOR CONTROL

1.  Be sure the power circuit and water supply to the generator are on.

2.   Press the ON/OFF button on the control until the temperature is displayed.

3.  The generator should produce steam in 5 to 10 minutes and will turn off automatically in 60 minutes or less depending on the set time. The control will  

     alternately display time remaining and the actual temperature at the sensor in your steam room every 5 seconds. 

4.  To change the time setting  press and hold the TIME button on the control. Continuing to hold the button will cause the time to increase in 5 minute increments 

     from the prior setting.  At 60 minutes the time setting will scroll backwards to 5 minutes. To shut down the generator press the ON/OFF button.

5.  To change the preset temperature setting press and hold the TEMP button on the control.  While continuing to hold the button, the temperature display will  

     increase in 1° increments from the prior setting to 125°F (52°C).  At 125°F (52°C) the temperature setting will decrease in 1° increment to the lowest setting  

     of 100°F (38°C).

6.  The TIME and TEMP set points are remembered by the exterior and interior Primary control for your next bath unless power to the steam generator is lost. 

  SECTION 3: TAKING A STEAMBATH

1.  Wait for the steam room to reach a comfortable temperature.  

2.  Remove clothing and jewelry.

3.  Enter the steam room and close the door to prevent steam from escaping.

4.  Relax and enjoy the warm steam releasing tense muscles and refreshing the entire body.  

5.  If your steam room has a shower a pleasant experience can be achieved by taking a warm shower with the steam.

6.  After a steambath a warm shower will give you a feeling of relaxation and is conducive to a good night’s rest.  A cold shower will refresh you and is a good  

     way to start a busy day or prepare you for an evening out.

 

SECTION  4:  MAINTENANCE OF YOUR  STEAM GENERATOR

The steam generator, steam head, fittings and plumbing connections should be inspected regularly for water leaks and damage. 

The Waterworks steam generator is equipped with an automatic drain valve system. The automatic drain valve system will flush the generator tank after each steam 

bath session following a 20-minute cool down period. This maintenance period of filling and flushing the generator shall last for a period of 3-5 minutes during which 

time no steam will emit from steam head(s).

Summary of Contents for WWSU08

Page 1: ...teamer should be the primary unit Each steamer should have its own automatic drain For commercial use we recommend checking with your local inspectors to confirm the steamer system is acceptable for y...

Page 2: ...age Important Safety Instruction 3 6 1 Mounting the Generator 7 8 2 Water Quality Requirements 8 3 Plumbing Instructions 9 12 4 Wiring Instructions 12 Electrical Information Chart 13 5 Bath Control In...

Page 3: ...ng must be installed by a licensed plumber in accordance with all applicable local and national codes Install indoors only Protect from freezing Generator must be level side to side and end to end The...

Page 4: ...erie doit tre install par un plombier sous licence conform ment tous les codes locaux et nationaux applicables Installer l int rieur uniquement Prot ger du gel G n rateur doit tre mise niveau lat rale...

Page 5: ...ERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 5 of 17 POST WARNING LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS tiquette d avertissement Ext rieur poste baiin de vapeur pour les avertissements re...

Page 6: ...utilis par toute personne y compris les enfants avec toutes leurs capacit s physiques sensorielles ou mentales ou qui manquent d exp rience ou de connaissances moins qu ils aient la supervision ou de...

Page 7: ...ervice Provide clearance for plumbing and electrical service and for element removal See Diagram 1 6 The steam line should slope to allow condensation to drain The mounting location should minimize th...

Page 8: ...ale to form on the internal surfaces This deposit or scale can interfere with the equipment s proper operation and even cause premature boiler or generator failure Concentration of impurities is gener...

Page 9: ...ator to allow for future servicing if needed and for emergency shut off Make sure the shut off is open providing water to the generator before turning it on IMPORTANT Water pressure required 20 100 ps...

Page 10: ...5 mm hole for the steam line entry Center the 1 2 copper steam pipe in the hole See Diagram 4 Terminate the steam line with a 1 2 NPT male adapter Stub the line out into the room 3 8 9 5 mm from the f...

Page 11: ...t have a drain valve installed to allow draining the tank for cleaning and maintenance A manual ball valve is supplied An electronic ball valve is available in the ADK Autodrain option When installed...

Page 12: ...dicated on the wire diagram for your voltage and phase This may require moving factory installed jumper Do not change the steamer s internal jumpers or wiring Only the supply wiring side of the termin...

Page 13: ...240 208 230 240 WWSU08 208 36 50 240 30 31 40 40 WWSU11 208 18 36 30 50 240 44 46 60 60 WWSU15 208 24 42 30 60 240 20 36 21 38 30 50 30 50 Nominal Amps at operating VAC 3 phz Recommended Breaker Mode...

Page 14: ...room The K3 and KT3 controls have a short tube on the back to help locate the control and to protect the cable end All of these controls connect to the steam generator s circuit board through Waterwor...

Page 15: ...or leaks 2 After the tank has filled to a safe level the heating elements will turn on Allow about 10 minutes for the steam to appear in the steam room 3 Once the steam is visible use the control to t...

Page 16: ...INSTALLATION AND SERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 16 of 17...

Page 17: ...INSTALLATION AND SERVICE INSTRUCTIONS 4211 1661 Rev A 01 28 2022 Page 17 of 17 240V MODELS 208V MODELS...

Page 18: ...drain For commercial use we recommend checking with your local inspectors to confirm the steamer system is acceptable for your use Many jurisdictions will require an ASME boiler for commercial use WA...

Page 19: ...ION continued IMPORTANT Before deciding on a mounting location please read through these installation instructions completely and take a careful look at al of the diagrams An exhaust fan installed out...

Page 20: ...YPICAL DRAIN LINES DIAGRAM 5 TYPICAL STEAM LINES IMPORTANT Input water pressure must be 20 100 psi 138 689 kPa If the generators are mounted in a place difficult for the home owner to access the water...

Page 21: ...instructions document 4211 1661 for details regarding plumbing of the individual steamers in your system INSTALL THE PRESSURE RELIEF VALVE Each steamer must have its own pressure safety valve 10psi 69...

Page 22: ...Refer to the wiring diagrams to determine your connection points and the necessary jumper connection Connections can be varied to use either single phase or 3 phase or 3 phase Neutral Connect the eart...

Page 23: ...s the ON OFF switch 6 Within one minute the units should again produce steam The generators should call for water once every two minutes or more depending on their power rating It s normal for the flo...

Page 24: ...TERIORCONTROLISMOUNTEDOUTSIDETHEENCLOSURETO ALLOW FOR EASY ADJUSTMENTS TO THE TIME AND TEMPERATURE STEAMBATH SCHEDULE THE INTERIOR CONTROLIS MOUNTED INSIDE THE ENCLOSURE TO ALLOW TEMPERATURE SENSING A...

Page 25: ...Description Page Important Safety Instructions 3 1A Exterior Control Overview 4 1B Interior Control Overview 4 2 Operation of Your WWSUP18 and WWSUP19 Controls 4 3 How toTake a Steambath 4 4 Maintena...

Page 26: ...hould consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a phy...

Page 27: ...The control will alternately display time remaining and the actual temperature at the sensor in your steam room every 5 seconds 4 To change the time setting press and hold the TIME button on the cont...

Page 28: ...emperature adjustment needs setting 1 See Section 3 Temperature Adjustment 2 Call WATERWORKS Service Department Control ON exterior or interior Control displays E001 Temperature sensor not connected 1...

Page 29: ...4209 55 REV A 01 28 2022 WWSU46 OWNERS MANUAL page 6...

Reviews: