4211-1661 01/28/2022
APPENDIX: SYSTEM INSTALLATION
APPENDIX: SYSTEM INSTALLATION
page 1
CAUTION
REDUCE THE RISK OF
1. Exit immediately if uncom fortable, dizzy or slee py. St aying too long in
a heated area is capa
ble of causing overheating.
REDUCE THE RISK OF
Use care when enter ing or exiting the steam room, floor ma y be slippe ry.
NOTE : For additional sa fety instructions, see owner's manual .
CA UTION!
Do not contact steam head . St ay at least 12" away
from hot steam escaping from the steam outlet.
OVERHEA TING AND SCALDING
2. Supe rvise children at all tim es .
3. Chec k with a doctor be fore use if pregnant, diabetic , in poor health or
under medical car e.
4. Breathing heated air in conjunction with consumption of alcohol, dr
ugs
or medication is capa ble of causing unconsciousnes s.
SLIPPING AND F ALL INJU RY
WARNING
4110-79
05-21-07
Waterworks’ steam generators are tested by Intertek-ETL Laboratory. The steam generators come assembled
and ready for installation. Check that the size and rating of the generator is suitable for your application, refer
to the Steam Room Construction and Generator Guide (Waterworks doc. 4211-36).
These steamers may be connected as a ganged system where one steamer controls one or two other steam-
ers. Bath controls connect to the primary steamer and the primary steamer connects to the second steamer
(and third steamer, if installed). This provides more power for large rooms and light commercial use. See
appendix to this document for details. We recommend choosing steamers which are closely matched in power.
The highest kW steamer should be the primary unit. Each steamer should have its own automatic drain.
For commercial use, we recommend checking with your local inspectors to confirm the steamer system is
acceptable for your use. Many jurisdictions will require an ASME boiler for commercial use: WATERWORKS
steamers are not boilers.
Note: These steamers may be configured for single or three phase power during installation
IMPORTANT
An exhaust fan installed outside the steam room is strongly recommended to remove excess steam
from the bathroom or shower area.
SECTION 1: GENERAL INFORMATION
ATMOS STEAM GENERATORS
FOR USE WITH STEAM SYSTEMS INCORPORATING
ONE WWSU PRIMARY STEAM GENERATOR AND
ONE OR TWO WWSU SECONDARY STEAM GENERATOR(S)
These instructions apply to
WWSU18 and WWSU21
Save these instructions! Read all instructions carefully before installation.
These instructions supplement the WWSU steamer installation instructions,
WATERWORKS document number 4211-1661
SECONDARY
GENERATOR
PRIMARY
GENERATOR
SECONDARY
GENERATOR
Electrical grounding is required on all
WATERWORKS Steam bath Generators.
All electrical supplies should be disconnected
when servicing generator.
All wiring must be installed by a licensed
electrical contractor in accordance with local
and national codes.
All plumbing must be installed by a licensed
plumber in accordance with all applicable
local and national codes.
Steam generators are
for indoor use only.
Steam generators are not for
space heating purposes.
Be certain that steam bath enclosures are
properly sealed to avoid water damage from
escaping steam. It is recommended that
100% silicone caulk be used to seal all pipes
and fittings. Steam must be prevented from
escaping into the wall cavity.
Never shut off the water to a
steam generator that is in use.
Electric Shock Hazard - High voltage exists
within this equipment. There are no user
serviceable parts in this equipment.
12 0
o
12 0
o