Troubleshooting

16

PROBLEM

 

CAUSE

 

CORRECTION

1. Reionator Pro Ultra

 fails to regenerate.

  A.  Bypass Valve in “Bypass” position. 

A.  Move bypass to “Normal” position.

 

 

B.  Valve may be disconnected 

B.  Make sure power is supplied to the 

 

 

  from power. 

 

transformer power pack and that the 

 

 

   

 

transformer power pack is securely 

 

 

   

 

connected to the PC Board of the Triton.

 

 

C.  Meter turbine is jammed or 

C.  Check meter turbine for foreign matter

 

 

  stalled. 

 

replace if necessary.

  

 

 

 

D.  Defective meter. 

D.  Replace meter.

 

 

E.  Hardness is set too low. 

E.  Check your water hardness

 

 

   

 

and follow procedure to set correct

 

 

   

 

hardness.

2. Reionator Pro Ultra

 delivers hard water.

 A.  Bypass valve is set to “Bypass.” 

A.  Move bypass to “Normal” position.

 

 

B.  No salt in brine tank. 

B.  Add salt to brine tank and                                                                                                                                              

                                 

       

 

maintain salt level above water level.

 

 

C.  Injectors or screen plugged. 

C.  Clean or replace injectors 

 

 

   

 

and screen.

  

 

 

 

D. Insufficient water flowing into  

D.  Check brine tank fill time and 

 

 

  brine tank. 

 

clean brine line flow control if plugged.

 

 

E.  Hot water tank hardness. 

E.  Repeated flushings of the hot water 

 

 

 

   

 

tank is required.

  

 

 

F.  Leak at distributor tube. 

F.  Make sure distributor tube is not cracked  

 

 

 

   

and check “O” ring and tube pilot.

 

 

G.  Internal valve leak. 

G.  Replace seals and spacers and/or piston. 

3. Unit uses too much salt. 

A.  Hardness set too high. 

A.  Check water hardness and follow

 

 

   

 

correct procedure to enter water hardness.

 

 

  

 

 

B.  Excessive water in brine tank. 

B.  See problem #7.

4. Loss of water pressure. 

A.  Iron buildup in line to water 

A.  Clean line to water conditioner.

 

 

  conditioner.

 

 

B.  Iron buildup in water conditioner. 

B.  Clean control and add resin cleaner to  

 

 

 

   

 

resin bed and increase frequency of  

 

 

 

   

 

regeneration.

 

 

C.  Inlet of control plugged due to foreign 

C.  Remove piston and clean control.

 

 

  material broken loose from pipes by

 

 

  recent work done on plumbing system.

 

5. Loss of resin through drain line.

 

A.  Air in water system. 

A.  Assure that well system has proper air 

 

 

   

 

eliminator control and check for dry 

 

 

   

 

well condition. 

6. Iron in conditioned water.

 

A.  Fouled resin bed. 

A.  Check backwash, brine draw and brine  

 

 

   

 

tank fill, increase frequency of 

 

 

   

 

regeneration and increase backwash time.

Summary of Contents for REIONATOR PRO ULTRA RXU13

Page 1: ...NER with Triton Electronic Control Valve INSTALLATION AND SERVICE MANUAL IAPMO R T certified to NSF ANSI Standards 42 and 44 for meeting or exceeding industry standards of aesthetic chlorine reduction...

Page 2: ...ness by gallons per day of people times 75 gallons person day For example there are 4 people in a home and you are installing a 32 000 grain Reionator Pro Ultra which has an optimum capacity of 16 080...

Page 3: ...rain and direct sunlight IMPORTANT Damage to the Reionator Pro Ultra as a result of exposure to the elements without the use of a weather cover will not be covered under the limited lifetime warranty...

Page 4: ...NECTION Install 1 2 I D plastic tubing from the hose barb located on the right side of the main control valve to an open drain Do not connect the drain directly to a sewer as this would violate sanita...

Page 5: ...nimum run between Reionator Pro unit and water heater hot cold hot water heater typical plumbing installation Triton Bypass Valve Important Brass or Plastic yoke assembly not shown is required to conn...

Page 6: ...ll 1 2 I D tubing not provided to the brine tank overflow fitting located on the side of the tank and run it to the drain The brine overflow is provided in case a situation should arise causing too mu...

Page 7: ...e tank Position mark on air check valve at same level as surface of salt grating to floor drain salt grating air check valve positioning mark brine well cap to aircheck overflow elbow brine well Figur...

Page 8: ...nd release the Set Time button The screen should change to the Set Time screen and the hour should flash Press and release either the or buttons until the desired hour of the day is reached AM or PM w...

Page 9: ...rs should stop flashing and the minutes should begin flashing Press either the or buttons to change the minutes as shown in Figure 9b When you ve finished setting the time press and release the Set Ti...

Page 10: ...e bypass has straight fittings The Triton uses no traditional fasteners e g screws instead clips threaded caps and nuts and snap type latches are used Caps and nuts only need to be firmly hand tighten...

Page 11: ...11 Bypass Valve Operation...

Page 12: ...e piston into the Brine Dn position Check the brine line for leaks or suction You should hear the valve drawing brine Continue to skip cycles by pressing and releasing the REGEN button wait for the mo...

Page 13: ...rn to service In step 5 you will set the valve to Regen Today so that it will regen tonight at the specified time If there is any residual chlorine it should be removed tonight Step 4 Make sure that t...

Page 14: ...a comes pre set from the factory to perform as a typical softener valve However there are certain settings that are specific to the customer s water situation that cannot be set at the factory This se...

Page 15: ...rom the Set HARDNESS screen press the NEXT button You should now see the Set REGEN DAY screen shown above Simply press the or button to change the day override IMPORTANT This screen is used to set the...

Page 16: ...ne flow control if plugged E Hot water tank hardness E Repeated flushings of the hot water tank is required F Leak at distributor tube F Make sure distributor tube is not cracked and check O ring and...

Page 17: ...oreign material and check control in various regeneration positions B Internal control leak B Replace seals and or piston assembly C Control valve jammed in brine or C Replace seals and or piston back...

Page 18: ...SAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE AND OR AFTER THE SYSTEM USAGE OF THE REIONATOR PRO ULTRA IN A MANNER OTHER THAN PRESCRIBED IN THE MANUFACTURER S WARRANTY WILL VOID THE...

Page 19: ...PTION PART NUMBER Resin Tank 13 x 54 09 03 1354BLK Xmid Brine Tank 09 04 1833BKC Brine Grid 18 09 04 119 Brine Well Assembly 3 5 X 30 09 04 240 Brine Overflow Elbow 07 05 004 Triton Control Valve 13 V...

Page 20: ...06 01 020 10 03 2017 800 FREEPORT PARKWAY 150 COPPELL TX 75019 888 254 8412 www watertech com...

Reviews: