INPUT VOLTAGE: 

110-120VAC @ 60Hz

OPERATING VOLTAGE: 

12VAC @ 60Hz

MIN WORKING PRESSURE: 

20-150 psi 

138-861 kPa

 

MIN OPERATING TEMPERATURE: 

40°-110° F 

4.4-43.30° C

MAX FLOW TO DRAIN DURING REGENERATION:  

 2.2 gpm 

8.3 l/min

FOR GENERAL INSTALLATION CONDITIONS, PLEASE SEE CARE & USE GUIDE.

THE REIONATOR PRO ULTRA™ IS A DIR (DEMAND INITIATED REGENERATION) SOFTENER WHICH 

COMPLIES WITH SPECIFIC PERFORMANCE 

SPECIFICATIONS INTENDED TO MINIMIZE THE USE OF REGENERANT BRINE IN ITS OPERATION. 

THIS WATER SOFTENER CONFORMS TO NSF/ANSI 42 FOR REDUCTION OF AESTHETIC CHLO-

RINE AND NSF/ANSI 44 FOR SOFTENING EFFICIENCY AS VERIFIED AND SUBSTANTIATED BY 

TEST DATA. WHILE TESTING WAS PERFORMED UNDER LABORATORY CONDITIONS, DUE TO 

VARYING WATER CONDITIONS ACTUAL PERFORMANCE MAY VARY.

THE REIONATOR PRO ULTRA HAS BEEN TESTED ACCORDING TO NSF/ANSI 42 FOR THE 

REDUCTION OF THE SUBSTANCES LISTED IN THE TABLE TO THE RIGHT. THE CONCENTRA-

TION OF THE SUBSTANCE IN THE WATER ENTERING THE SYSTEM WAS REDUCED TO A 

CONCENTRATION LESS THAN OR EQUAL TO THE PERMISSIBLE LIMIT FOR WATER LEAVING 

THE SYSTEM AS SPECIFIED BY NSF/ANSI 42.

THE REIONATOR PRO ULTRA IS NOT INTENDED FOR USE IN TREATING WATER THAT IS MI-

CROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION 

BEFORE AND/OR AFTER THE SYSTEM. 

USAGE OF THE REIONATOR PRO ULTRA IN A MANNER OTHER THAN PRESCRIBED IN THE 

MANUFACTURER’S WARRANTY WILL VOID THE REIONATOR LIMITED LIFETIME WARRANTY.

(SEE OWNER’S MANUAL FOR FULL WARRANTY INFORMATION.)

AS WITH ANY APPLIANCE, PROPER OPERATION AND MAINTENANCE IS REQUIRED 

TO ENSURE TROUBLE-FREE OPERATION. PLEASE CONSULT YOUR LOCAL AUTHO

-

RIZED WATERTECH DEALER FOR SERVICE.

Model

*1

Softening Efficiency @ 

Stated Salt Setting

(Grains Per Pound)

2

Softening Capacity @ 

Stated Salt Setting 

(Grains Per Gallon)

Maximum Recom

-

mended Hardness 

(Grains Per Gallon)

Maximum Recommend

-

ed Flow Rate / Service 
Flow Rate (Gallons per 

minute)

Maximum Flow to 

Drain During

 Regeneration

(Gallons per minute)

@PSID

Total Bed 

Depth (FT

3

)

RXU13

3998 @ 4.7 lbs.

18,901 @ 4.7 lbs.

45

11.0

2.2

15

2.350

Model

Aesthetic Chlorine

Reduction (Gallons)

RXU13

1180

The efficiency is only valid at the stated salt dosage and maximum service flow. 

 

 

Softening efficiency values based on NaCl as the regenerant salt.

2.

Softening capacity values based on NaCl as the regenerant salt.

Specifications

WaterTech recommends the use of Potassium Chloride (KCl) as a regenerant salt.

Efficiency rated softeners shall have a rated 
salt efficiency of not less than 3350 grains 
of total hardness exchange per pound of 
salt, and shall not deliver more than its 
listed rating.

Summary of Contents for REIONATOR PRO ULTRA RXU13

Page 1: ...NER with Triton Electronic Control Valve INSTALLATION AND SERVICE MANUAL IAPMO R T certified to NSF ANSI Standards 42 and 44 for meeting or exceeding industry standards of aesthetic chlorine reduction...

Page 2: ...ness by gallons per day of people times 75 gallons person day For example there are 4 people in a home and you are installing a 32 000 grain Reionator Pro Ultra which has an optimum capacity of 16 080...

Page 3: ...rain and direct sunlight IMPORTANT Damage to the Reionator Pro Ultra as a result of exposure to the elements without the use of a weather cover will not be covered under the limited lifetime warranty...

Page 4: ...NECTION Install 1 2 I D plastic tubing from the hose barb located on the right side of the main control valve to an open drain Do not connect the drain directly to a sewer as this would violate sanita...

Page 5: ...nimum run between Reionator Pro unit and water heater hot cold hot water heater typical plumbing installation Triton Bypass Valve Important Brass or Plastic yoke assembly not shown is required to conn...

Page 6: ...ll 1 2 I D tubing not provided to the brine tank overflow fitting located on the side of the tank and run it to the drain The brine overflow is provided in case a situation should arise causing too mu...

Page 7: ...e tank Position mark on air check valve at same level as surface of salt grating to floor drain salt grating air check valve positioning mark brine well cap to aircheck overflow elbow brine well Figur...

Page 8: ...nd release the Set Time button The screen should change to the Set Time screen and the hour should flash Press and release either the or buttons until the desired hour of the day is reached AM or PM w...

Page 9: ...rs should stop flashing and the minutes should begin flashing Press either the or buttons to change the minutes as shown in Figure 9b When you ve finished setting the time press and release the Set Ti...

Page 10: ...e bypass has straight fittings The Triton uses no traditional fasteners e g screws instead clips threaded caps and nuts and snap type latches are used Caps and nuts only need to be firmly hand tighten...

Page 11: ...11 Bypass Valve Operation...

Page 12: ...e piston into the Brine Dn position Check the brine line for leaks or suction You should hear the valve drawing brine Continue to skip cycles by pressing and releasing the REGEN button wait for the mo...

Page 13: ...rn to service In step 5 you will set the valve to Regen Today so that it will regen tonight at the specified time If there is any residual chlorine it should be removed tonight Step 4 Make sure that t...

Page 14: ...a comes pre set from the factory to perform as a typical softener valve However there are certain settings that are specific to the customer s water situation that cannot be set at the factory This se...

Page 15: ...rom the Set HARDNESS screen press the NEXT button You should now see the Set REGEN DAY screen shown above Simply press the or button to change the day override IMPORTANT This screen is used to set the...

Page 16: ...ne flow control if plugged E Hot water tank hardness E Repeated flushings of the hot water tank is required F Leak at distributor tube F Make sure distributor tube is not cracked and check O ring and...

Page 17: ...oreign material and check control in various regeneration positions B Internal control leak B Replace seals and or piston assembly C Control valve jammed in brine or C Replace seals and or piston back...

Page 18: ...SAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE AND OR AFTER THE SYSTEM USAGE OF THE REIONATOR PRO ULTRA IN A MANNER OTHER THAN PRESCRIBED IN THE MANUFACTURER S WARRANTY WILL VOID THE...

Page 19: ...PTION PART NUMBER Resin Tank 13 x 54 09 03 1354BLK Xmid Brine Tank 09 04 1833BKC Brine Grid 18 09 04 119 Brine Well Assembly 3 5 X 30 09 04 240 Brine Overflow Elbow 07 05 004 Triton Control Valve 13 V...

Page 20: ...06 01 020 10 03 2017 800 FREEPORT PARKWAY 150 COPPELL TX 75019 888 254 8412 www watertech com...

Reviews: