PROBLEM

 

CAUSE

 

CORRECTION

7A.  Excessive water in brine tank.

 

A.  Plugged drain line flow control. 

A.  Clean flow control.

7B.  Salt water in service line.

 

B.  Plugged injector system. 

B.  Clean injector and replace screen.

 

C.  Plugged or kinked drain line. 

C.  Clean and/or straighten 

 

 

 

  the drain line.

 

D.  Foreign material in brine valve. 

D.  Clean or replace brine valve.

 

E.  Foreign material in brine line flow 

E.  Clean brine line flow control .

 

 

control.

 

  

  

8. Reionator Pro Ultra™ fails to draw brine.

  A.  Brine line flow control is plugged. 

A.  Clean brine line flow control.

 

B.  Injector is plugged. 

B.  Clean or replace injectors.

 

C.  Injector screen plugged. 

C.  Replace screen.

 

D.  Line pressure is too low. 

D.  Increase line pressure (line 

 

 

 

  pressure must be at least

  

 

 

  20 PSI at all times).

 

E.  Connections to brine elbow and valve 

E.  Check fittings for correct 

 

 

and brine elbow in brine tank drawing 

  assembly of nut parts. Check 

 

 

air 

  to see if nuts are snug.

 

  

  

 

F.  Internal Control Leak. 

F.  Change seals and spacers and/or

 

 

 

  position assembly.

 

10. Drain flows continuously.

 

A.  Foreign material in control. 

A.  Remove piston assembly and 

 

 

 

  inspect bore, remove foreign

 

 

 

  material and check control in

 

 

 

  various regeneration positions.

 

B.  Internal control leak. 

B.  Replace seals and/or piston 

 

 

 

  assembly.

 

C.  Control valve jammed in brine or 

C.  Replace seals and/or piston 

       

 

backwash position. 

  assembly. 

 

GENERAL SERVICE HINTS FOR METER CONTROL

Problem: 

Softener delivers hard water

Hard water delivered from the Reionator Pro Ultra™ may indicate that the unit has exceeded it’s reserve capacity.

Correction:

 

Check your water hardness and make sure that you have set the hardness correctly. Hardness set too low will cause

 

your Reionator Pro Ultra™ not to regenerate often enough.

Correction:

 

Check to ensure a good connection from the meter to the PC board on the Triton. Check for loose or broken wires

 

and reconnect to the PC board if necessary.

Correction:

 

Check the meter turbine to ensure that it rotates freely. Check for foreign matter in the meter shaft. Replace meter

 

if necessary.

Correction: 

From the time of day screen on the Triton, press the NEXT button to see the softener usage. If there is a tap or hose bib nearby

 

 

that is connected to the system, place a 5-gallon bucket underneath and fill it. Check the capacity remaining to see if it has

 

 

decreased by 5 gallons. If not, replace the meter. If replacing the meter does not solve the problem, replace the PC board.

 

Summary of Contents for REIONATOR PRO ULTRA RXU13

Page 1: ...NER with Triton Electronic Control Valve INSTALLATION AND SERVICE MANUAL IAPMO R T certified to NSF ANSI Standards 42 and 44 for meeting or exceeding industry standards of aesthetic chlorine reduction...

Page 2: ...ness by gallons per day of people times 75 gallons person day For example there are 4 people in a home and you are installing a 32 000 grain Reionator Pro Ultra which has an optimum capacity of 16 080...

Page 3: ...rain and direct sunlight IMPORTANT Damage to the Reionator Pro Ultra as a result of exposure to the elements without the use of a weather cover will not be covered under the limited lifetime warranty...

Page 4: ...NECTION Install 1 2 I D plastic tubing from the hose barb located on the right side of the main control valve to an open drain Do not connect the drain directly to a sewer as this would violate sanita...

Page 5: ...nimum run between Reionator Pro unit and water heater hot cold hot water heater typical plumbing installation Triton Bypass Valve Important Brass or Plastic yoke assembly not shown is required to conn...

Page 6: ...ll 1 2 I D tubing not provided to the brine tank overflow fitting located on the side of the tank and run it to the drain The brine overflow is provided in case a situation should arise causing too mu...

Page 7: ...e tank Position mark on air check valve at same level as surface of salt grating to floor drain salt grating air check valve positioning mark brine well cap to aircheck overflow elbow brine well Figur...

Page 8: ...nd release the Set Time button The screen should change to the Set Time screen and the hour should flash Press and release either the or buttons until the desired hour of the day is reached AM or PM w...

Page 9: ...rs should stop flashing and the minutes should begin flashing Press either the or buttons to change the minutes as shown in Figure 9b When you ve finished setting the time press and release the Set Ti...

Page 10: ...e bypass has straight fittings The Triton uses no traditional fasteners e g screws instead clips threaded caps and nuts and snap type latches are used Caps and nuts only need to be firmly hand tighten...

Page 11: ...11 Bypass Valve Operation...

Page 12: ...e piston into the Brine Dn position Check the brine line for leaks or suction You should hear the valve drawing brine Continue to skip cycles by pressing and releasing the REGEN button wait for the mo...

Page 13: ...rn to service In step 5 you will set the valve to Regen Today so that it will regen tonight at the specified time If there is any residual chlorine it should be removed tonight Step 4 Make sure that t...

Page 14: ...a comes pre set from the factory to perform as a typical softener valve However there are certain settings that are specific to the customer s water situation that cannot be set at the factory This se...

Page 15: ...rom the Set HARDNESS screen press the NEXT button You should now see the Set REGEN DAY screen shown above Simply press the or button to change the day override IMPORTANT This screen is used to set the...

Page 16: ...ne flow control if plugged E Hot water tank hardness E Repeated flushings of the hot water tank is required F Leak at distributor tube F Make sure distributor tube is not cracked and check O ring and...

Page 17: ...oreign material and check control in various regeneration positions B Internal control leak B Replace seals and or piston assembly C Control valve jammed in brine or C Replace seals and or piston back...

Page 18: ...SAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE AND OR AFTER THE SYSTEM USAGE OF THE REIONATOR PRO ULTRA IN A MANNER OTHER THAN PRESCRIBED IN THE MANUFACTURER S WARRANTY WILL VOID THE...

Page 19: ...PTION PART NUMBER Resin Tank 13 x 54 09 03 1354BLK Xmid Brine Tank 09 04 1833BKC Brine Grid 18 09 04 119 Brine Well Assembly 3 5 X 30 09 04 240 Brine Overflow Elbow 07 05 004 Triton Control Valve 13 V...

Page 20: ...06 01 020 10 03 2017 800 FREEPORT PARKWAY 150 COPPELL TX 75019 888 254 8412 www watertech com...

Reviews: