Version 3.07 - 0310

GB

User Manual

Vanvex Optima 180

Domestic Hot Water

Summary of Contents for Vanvex Optima 180

Page 1: ...Version 3 07 0310 GB User Manual Vanvex Optima 180 Domestic Hot Water ...

Page 2: ...ription Optima180 6 2 2 Extra capacity 6 2 3 Operation safety 6 2 4 Warnings 6 3 Maintaining 3 1 Communication box 7 3 2 Cooling System and fan 7 3 3 Water circuit and tank 7 3 4 Cancelling operation 7 4 Fault finding 4 1 Highpressure switch 8 4 2 Safety breaker for heating element 8 4 3 Heat pump will not run 8 5 Electric diagramme 9 6 Flow diagramme 10 Subject to Technical Modifications ...

Page 3: ...0 the electric element will not turn on if needed At outdoor temperatures below 0 C it is an advantage to use the electric element Factory setting 0 P3 The operating thermostat is pressed The required domestic water temperature may be set between 0 55 C which is heated by the heat pump Factory setting 52 0 C P4 Stop defrosting The level and operating thermostat buttons are pressed simultaneously A...

Page 4: ... possible to automatically let the electrical heater help heating the water when the intake air temperature is below the temperature set in E10 The function is activated when the value has been set to 2 fresh air operation Factory setting 0 E10 Operating in cold surroundings When activating the function menu E9 the temperature at which the compressor will stop or the heater will assist may be set ...

Page 5: ...0 E26 Vent level 3 If extraction from the building at a specific length of time is required it is possible to change to level 3 The fan will now run for the set period regardless the need for heating water Thereafter the system will return to level 2 This menu option is used to specify the speed at which the fans should run when the set period has been chosen The speed may be set to 0 100 Factory ...

Page 6: ...e control is forced to run at 3rd speed This may be used in order to achieve more extract in e g bathroom while taking a shower When breaking the short circuit on the input pins to T4 the control will return to its previous step Defrosting When the temperature difference between the temperature upstream of the cooling surface and the temperature of the cooling surface becomes too large as happens ...

Page 7: ...n the cold water pipe prevents the water from flowing back into the cold water pipe This means that the pressure in the tank will increase to the maximum pressure permitted by the safety valve at which point it will open and allow the surplus water to escape If the safety valve did not open the tank would burst To make sure that the safety valve is working properly it should be inspected several t...

Page 8: ...y breaker protects the equipment against overheating during heating with the electrical heating element The safety breaker is mounted on the heater If the adjusted value 90 is exceeded the heating coil will disconnect It can be reconnected when the temperature is below 90 To do this the power to the equipment must be off front door dismantled and the front cover of the heating element dismantled T...

Page 9: ...9 Optima 180 Notes ...

Page 10: ...10 Optima 180 Notes ...

Page 11: ...11 Optima 180 Notes ...

Page 12: ...ium Artiklima bvba B 9220 Hamme Tel 32 0 52 41 25 41 Fax 32 0 52 41 29 66 E Mail info artiklima be Great Britain Total Home Environment Ltd GB Moreton in Marsh GL 56 0JQ Tel 44 0 845 260 0123 Fax 44 0 1608 652490 E Mail genvex totalhome co uk Ireland N I ECO Systems Ireland Ltd Co Antrim BT54 6PH Tel UK 028 ROI 048 44 2076 8708 Fax UK 028 ROI 048 44 2076 9781 E Mail info ecosystemsireland com Schw...