RS1
- To Skip A Regeneration -
1. For vacations or extended periods of absence, the power supply can be disconnected from the control valve.
2. Upon return, plug in cord and reset the time of day.
- General Care and Cleaning -
1. Do not place heavy or sharp objects on water softener or cabinet.
2. Use only mild soap and warm water to clean exterior of the unit. Never use harsh, abrasive cleaners.
3. Protect the water softener and drain line from freezing.
4. Reset time for daylight saving time periods.
5. Inspect and clean the brine tank when sediment appears in the bottom of the salt compartment.
6. Always keep the brine tank supplied with good quality salt, a type designed for use in water softeners.
Installation
11
Normal Operation
1.
Home Display
The RS1
model will alternate the Time of Day and Gallons left until the next regeneration. The meter will count
down to zero (0000) and then regenerate at the scheduled time set.
Starting Extra Regeneration Cycle
1.
To Start
Delayed Extra Cycle
- Press and hold the
Set/Change
button for 3 seconds until the display reads ‘0000’
- Regeneration cycle will initiate at the next designated regeneration time.
2.
To start
Immediate Extra Cycle
First complete above step.
- With Gallons Remaining Until Next Regeneration at ‘0000’,
- Press and hold the
Set/Change
button.
- After 3 seconds, the regeneration cycle will begin.
3. To
Fast Cycle
thru regeneration
First complete above 2 steps.
Note
:
Press and hold the
Set/Change
button for 3 seconds to advance to the next cycle step.
Fast Cycle is not necessary unless desired to manually step through each cycle step.
(Repeat until valve returns to the home display)
Softeners
Default (Min)
Step 1
Backwash
10
Step 2
Brine & Rinse
60
Step 3
Rapid Rinse
10
Step 4
Brine Refill
9 lbs/ cu ft