background image

 

                                                                                                                

                       

 

 

 

 

 

 

 

 

 

 

 

 

 

                                       

RS1

                                                                                         

SYMPTOM

PROBABLE CAUSE

CORRECTION

7.  Excessive  Water  in                               

    Brine Tank and / or 

    Salty Water to Service

Plugged drain line or drain line control

Check flow to drain. Clean drainline 
flow control button

Dirty or damaged brine valve

Clean or replace brine valve.

Plugged injector or screen

Clean or replace injector screen. 

Low inlet pressure

Increase pressure to allow injector to 
perform properly. (20 psig minimum)

Excessive brine refill cycle time

Lower brine refill time.

8. Softener Fails to Use 

    Salt

Check items listed in #1
Improper control valve programming

Check and reset programming

Plugged / restrict drain line

Clean drain line and / or flow control 
button

Injector and / or screen is plugged

Clean or replace injector and screen

No water in brine tank

Check for restriction in BLFC. Ensure 
safety float is not stuck. Check brine 
tank for leaks. 

Water pressure is too low

Line pressure must be at least 20 psi.

Brine line injects air during brine draw

Check brine line connectionsfor air 
leaks

Internal control leak

Call dealer. Check piston, seals and 
spacers for scratches and dents.

9. Continuous Flow to        

    Drain

Foreign material in control piston and 
seals

Call dealer. Clean valve and replace 
piston and seals. 

Internal control leak

Same as above.

Valve jammed in backwash, brine or 
rapid rinse position

Same as above.

Motor stopped or jammed

Check for jammed piston. Replace 
piston and seals. Replace motor if 
motor is unresponsive. 

23

Troubleshooting Guide

Error Codes

 There are five (5) error codes which could indicate a possible problem with the control valve:
 

Error 2 -

  Valve is searching for homing slot.

                           Allow valve to run until homing slot is found or new error code appears.

 

Error 3 -

  No encoder slots are being seen.

 

 

     Check encoder connection. If encoder is connected. Check valve body for debris 

 

 

     and replace seals. Inspect piston and replace if worn.

 

Error 4 -

  Unable to find homing slot.

 

 

     Check encoder wheel for debris.

 

Error 5 -

  Motor overload.

 

                Check valve body for debris. Replace seals. Inspect piston and replace if worn. 

                           Check motor operation and replace motor if unresponsive.

 

Error 6 -  

No power to motor. Check motor connections, replace motor if unresponsive.

Summary of Contents for rs1

Page 1: ...RS1 RS1 Softener Manual Installation Operation Manual CABINET Water Softener...

Page 2: ...ation Page 5 Master Programming Page 12 Utilizing Bluetooth Page 14 Powerhead Assembly Page 15 Valve Body Assembly Page 16 Cabinet Body Assembly Page 17 Bypass Assembly Page 18 Additional Information...

Page 3: ...that attacks some plastic materials It is recommended that Teflon tape be used to seal plastic Noryl threaded fittings Softener Specifications 3 General Specifications CD24 CD24X CD32 CD32X Grains Cap...

Page 4: ...oft water The surfaces of these beads are covered with sodium ions As hard water enters the mineral tank and comes into contact with the resin an ex change of ions takes place as dissolved Calcium and...

Page 5: ...lumbing connections A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the inlet to a water heater to prevent damage due to back up of hot water DO NO...

Page 6: ...assumed by the manufacturer of the softener should this occur Caution If sweat soldering copper pipe remember to always use lead free solder and flux cover bypass valve with wet rags to prevent heat...

Page 7: ...low during regeneration Elbows or other fittings must be kept at a bare minimum Note Where the drain line is elevated above the control valve or exceeds 20 in length 3 4 I D drain line tubing should b...

Page 8: ...ss the Menu Enter button Time of Day will flash 2 To set the Time of Day press the Set Change button First digit will flash Example 12 00 To change digit value press the Set Change button To accept th...

Page 9: ...run to drain for 3 to 4 minutes Warning Close valve on bypass prior to selecting the backwash position After backwash position has been established slightly open bypass to evacuate air from the media...

Page 10: ...d Final Check 1 Be certain the bypass valve is in the SERVICE position 2 Make sure the power supply is connected to an uninterrupted 115 volt outlet 3 Check that the time of day is set 4 Double check...

Page 11: ...Time of Day and Gallons left until the next regeneration The meter will count down to zero 0000 and then regenerate at the scheduled time set Starting Extra Regeneration Cycle 1 To Start Delayed Extr...

Page 12: ...is used to set the maximum amount of time in days the unit can be in service without regeneration This setting is identified by the letter A in the left digit Regeneration will begin at the scheduled...

Page 13: ...1 ON BE 0 OFF 7 Bluetooth Password BBPP is displayed for one second then password is displayed 8 To Exit the Master Programming Mode press the Menu Enter button until time of day returns Note If no bu...

Page 14: ...this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance coul...

Page 15: ...Number Qty 1 Secondary Plate 20016X002 1 2 Encoder Wheel 20001X007 1 3 Encoder Board 20016X200 1 4 Main Plate 20016X001 1 5 Motor 20016X200 1 6 Brine Cam 20001X122 1 7 Main Gear 20001X120 1 6 1 2 7 4...

Page 16: ...Ferrule 20251X305 2 12 Injector Cap Screw 20001X226 1 13 Injector Cap 20001X223 1 Ref Description Part Qty 14 Injector Seal 20001X224 1 15 Injector White 20001X219 1 16 Screen 20001X222 1 17 Plug 2000...

Page 17: ...6X011 1 7 Bluetooth Board EVB 019 CAB 1 8 Rubber Key Pad EVA 019 KEY 1 9 Front Insert 20016X012 1 10 Salt Paddle R2014X002 1 11 Salt Sensor Pivot includes 12 15 R2014X005 1 12 Salt Sensor Mount 1 13 S...

Page 18: ...y Ref Description Part Qty 1A Meter Assembly Turbine Complete 20003X200 1 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 2056...

Page 19: ...s and remove cap 3 Remove injector assembly Apply silicone lubricant to new injector assembly O rings and install Be sure to push injector assembly tightly so O rings are seated Install a new screen 4...

Page 20: ...to assure proper function Make sure control valve is returned to the service position 13 Make sure there is enough salt in the brine tank 14 Start regeneration cycle manually if water is hard 15 Repla...

Page 21: ...body Install new seals and spacers individually pressing around the outer edge of each seal to make sure it is seated When all seals and spacers are seated properly you will have a 1 4 of space betwe...

Page 22: ...ver it Resin fouling Call dealer Find out how to confirm it Clean the resin and prevent future fouling Poor distribution channeling uneven bed surface Call dealer Check backwash flow Regenerate more f...

Page 23: ...tionsfor air leaks Internal control leak Call dealer Check piston seals and spacers for scratches and dents 9 Continuous Flow to Drain Foreign material in control piston and seals Call dealer Clean va...

Page 24: ...RS1 WATERSOFT 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www WATERSOFT com...

Reviews: